ObjectivesThe study sought to determine the coronary flow characteristics of angiographically intermediate stenoses classified as discordant by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR).BackgroundDiscordance between FFR and iFR occurs in up to 20% of cases. No comparisons have been reported between the coronary flow characteristics of FFR/iFR discordant and angiographically unobstructed vessels.MethodsBaseline and hyperemic coronary flow velocity and coronary flow reserve (CFR) were compared across 5 vessel groups: FFR+/iFR+ (108 vessels, n = 91), FFR–/iFR+ (28 vessels, n = 24), FFR+/iFR– (22 vessels, n = 22), FFR–/iFR– (208 vessels, n = 154), and an unobstructed vessel group (201 vessels, n = 153), in a post hoc analysis of the largest combined pressure and Doppler flow velocity registry (IDEAL [Iberian-Dutch-English] collaborators study).ResultsFFR disagreed with iFR in 14% (50 of 366). Baseline flow velocity was similar across all 5 vessel groups, including the unobstructed vessel group (p = 0.34 for variance). In FFR+/iFR– discordants, hyperemic flow velocity and CFR were similar to both FFR–/iFR– and unobstructed groups; 37.6 (interquartile range [IQR]: 26.1 to 50.4) cm/s vs. 40.0 [IQR: 29.7 to 52.3] cm/s and 42.2 [IQR: 33.8 to 53.2] cm/s and CFR 2.36 [IQR: 1.93 to 2.81] vs. 2.41 [IQR: 1.84 to 2.94] and 2.50 [IQR: 2.11 to 3.17], respectively (p > 0.05 for all). In FFR–/iFR+ discordants, hyperemic flow velocity, and CFR were similar to the FFR+/iFR+ group; 28.2 (IQR: 20.5 to 39.7) cm/s versus 23.5 (IQR: 16.4 to 34.9) cm/s and CFR 1.44 (IQR: 1.29 to 1.85) versus 1.39 (IQR: 1.06 to 1.88), respectively (p > 0.05 for all).ConclusionsFFR/iFR disagreement was explained by differences in hyperemic coronary flow velocity. Furthermore, coronary stenoses classified as FFR+/iFR– demonstrated similar coronary flow characteristics to angiographically unobstructed vessels.
Increased tidal volume and decreased chest wall compliance both increase the change in intrathoracic pressures and the value of the dynamic indices during mechanical ventilation. Additionally, the transmural pressure of the vena cava is decreased, whereas the transmural pressure of the right atrium is not changed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.