In the TPS (Taiwan Photon Source) facility, current stability of the electron beam depends on the bending magnet power supply and an orbit FOFB system to compensate the magnetic field. Due to the output current stability of the bending magnet power supply drifts with temperature so the orbit FOFB system should be applied to fine tune magnetic field and the photon beam should circulate in storage ring. In this paper, to stabilize the temperature of regulation circuit’s temperature box of the bending magnet power supply, the long-term output current stability is improve from ± 50ppm to ± 10ppm, and orbit FOFB system substantially reduce the tune X of beam position, effectively increasing the beam current stability and quality. In the TPS (Taiwan Photon Source) facility, current stability of the electron beam depends on the bending magnet power supply and an orbit FOFB system to compensate the magnetic field. Due to the output current stability of the bending magnet power supply drifts with temperature so the orbit FOFB system should be applied to fine tune magnetic field and the photon beam should circulate in storage ring. In this paper, to stabilize the temperature of regulation circuit’s temperature box of the bending magnet power supply, the long-term output current stability is improve from ± 50ppm to ± 10ppm, and orbit FOFB system substantially reduce the tune X of beam position, effectively increasing the beam current stability and quality.
At SRRC, a precision output current monitoring system is installed to monitor the output performance of all the booster/storage ring power supplies. Accurate DC current transformers (DCCTs) are attached to the output terminal of every power supply system. Each transformer's gain/offset are carefully calibrated against high precision current source and approximated using high-order polynomial curve fitting. The output of each DCCT is connected to multi-channels data logger for realtime data collection, the collected data are calibrated using the interpolated DCCT gain/offset value. A PC station is set up to serve as host to store the current output for real-time monitoring. This monitoring system provide a precise real-time database for rapid fault diagnosing whenever there is malfunction of the beam operation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.