Corrosion fatigue crack growth (FCG) behavior of alloy 600 (UNS N06600) sensitized at 1,100°C/0.5 h + 700°C/5 h in 0.1 M sodium thiosulfate (Na 2 S 2 O 3 ) solution at room temperature under applied anodic potential conditions was investigated using the fracture mechanics technique. Results indicated the FCG rate depended upon the testing frequency and the applied potential. At a frequency of 1 Hz, FCG rates were independent of applied potential and nearly the same as those tested in a N 2 atmosphere. However, at a frequency of 0.1 Hz, the FCG rate increased with increasing applied potential. Moreover, the competition between environmental and mechanical effects influenced the fracture morphology of the corrosion fatigue of sensitized alloy 600.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.