OBJECTIVES Repair of tetralogy of Fallot (ToF) can be challenging in the presence of an abnormal coronary artery (CA) in 5–12% of cases. The aim of this study was to report our experience with ToF repair without the systematic use of a right ventricle-to-pulmonary artery (RV-PA) conduit. METHODS We conducted a monocentric retrospective study from 2000 to 2016, including 943 patients with ToF who underwent biventricular repair, of whom 8% (n = 76) presented with an abnormal CA. Mean follow-up time was 50 months (1 month–18 years). RESULTS The most frequent CA anomaly was the left descending artery arising from the right CA (n = 47, 61.8%). The median age at repair was 7.7 months (1.8 months–16 years). Thirteen patients (17%) required prior palliation, mostly systemic pulmonary shunts for anoxic spells in the neonatal period. Surgical repair allowed us to preserve the annulus in 40 patients (53%) by combining PA trunk plasty, commissurotomy and infundibulotomy under the abnormal CA. If the annulus had to be opened (n = 35, 46%), a transannular patch was inserted after a vertical incision of the PA trunk and extended obliquely on the RV over the anomalous crossing CA (with an infundibulotomy under the abnormal CA). Three patients (4%) required the insertion of an RV-PA conduit (1 valved tube and 2 RV-PA GORE-TEX tubes with annulus conservation). The early mortality rate was 4% (n = 3); none of the deaths was coronary related. Four patients (5%) required reoperation (2 early and 2 late reoperations) for residual pulmonary stenosis, 3 of whom had annulus preservation during the initial repair. The mean RV/left ventricle (LV) pressure ratio and an RV/LV pressure ratio >2/3 were identified as risk factors for right ventricular outflow tract (RVOT) reinterventions (P = 0.0026, P = 0.0085, respectively), RVOT reoperations (P = 0.0002 for both) and reoperation for RVOT residual stenosis (P = 0.0002, P = 0.0014, respectively). Two patients underwent pulmonary valve replacement. Freedom from late reoperation was 100% at 1 year, 97% at 5 years and 84% at 10 and 15 years. CONCLUSIONS Repair of ToF and abnormal CA can be performed without an RV-PA conduit, with an acceptable low reintervention rate. The high early mortality rate in this series remains a concern. If any doubt remains about the surgical relief of the RVOT obstruction, the RV/LV pressure ratio should always be measured in the operating room.
Background. The impact of the COVID-19 pandemic on hospitalization for cardiac infections is not well known. We aimed to evaluate the nationwide trends in hospital stays for myocarditis and endocarditis cases before, during and after the nationwide lockdown for the COVID-19 pandemic in France. We then aimed to describe the proportion of myocarditis and endocarditis patients with and without COVID-19 and their clinical characteristics. Methods. Hospitalized cases of cardiac infection were extracted from the French National Discharge database, which collects the medical records of all patients discharged from all public and private hospitals in France. Age, sex, and available cardiovascular risk factors were compared between stays with and without COVID-19 during the lockdown. Results. The number of myocarditis cases was 11% higher in 2020, compared to the average of the three prior years. In 2020, 439 of 3727 cases of myocarditis were associated with COVID-19. For endocarditis, there was an increase in cases by 7% in 2020 versus prior years. For endocarditis, 3% (240 of 8128 cases) of patients with endocarditis had COVID-19. For myocarditis, older age, hypertension, diabetes, obesity, and atrial fibrillation were more frequent in patients with COVID-19 than in those without. For endocarditis, only hypertension was more frequent in patients with COVID-19 than in those without. Conclusion. Our study reports an increase in hospitalizations for both myocarditis and endocarditis in 2020, possibly related to the COVID-19 pandemic. Interestingly, the trends differ according to the COVID-19 status. Knowledge of the factors associating myocarditis or endocarditis and COVID-19 may improve the quality and the type of monitoring for people with COVID-19, the identification of patients at risk of cardiac infections, and the treatment of COVID-19 patients.
Introduction Aneurysms of the ascending aorta (AA) correspond to a dilatation of the ascending aorta that progressively evolves over several years. The main complication of aneurysms of the ascending aorta is type A aortic dissection, which is associated with very high rates of morbidity and mortality. Prophylactic ascending aorta replacement guidelines are currently based on maximal AA diameter. However, this criterion is imperfect. Stretching tests on the aorta carried out ex-vivo make it possible to determine the elastic properties of healthy and aneurysmal aortic fragments (tension test, resistance before rupture). For several years now, cardiac magnetic resonance imaging (MRI) has provided another means of evaluating the elastic properties of the aorta. This imaging technique has the advantage of being non-invasive and of establishing aortic compliance (local measurement of stiffness) without using contrast material by measuring the variation of the aortic surface area during the cardiac cycle, and pulse wave velocity (overall stiffness of the aorta). Materials and methods Prospective single-center study including 100 patients with ascending aortic aneurysm requiring surgery. We will perform preoperative cine-MRI and biomechanical laboratory stretching tests on aortic samples collected during the cardiac procedure. Images will be acquired with a 3T MRI with only four other acquisitions in addition to the conventional protocol. These additional sequences are a Fast Low Angle Shot (FLASH)-type sequence performed during a short breath-hold in the transverse plane at the level of the bifurcation of the pulmonary artery, and phase-contrast sequences that encodes velocity at the same localization, and also in planes perpendicular to the aorta at the levels of the sino-tubular junction and the diaphragm for the descending aorta. For ex-vivo tests, the experiments will be carried out by a biaxial tensile test machine (ElectroForce®). Each specimen will be stretched with 10 times of 10% preconditioning and at a rate of 10 mm/min until rupture. During the experiment, the tissue is treated under a 37°C saline bath. The maximum elastic modulus from each sample will be calculated. Results The aim of this study is to obtain local patient-specific elastic modulus distribution of the ascending aorta from biaxial tensile tests and to assess elastic properties of the aorta using MRI, then to evaluate the correlation between biaxial tests and MRI measurements. Discussion Our research hypothesis is that there is a correlation between the evaluation of the elastic properties of the aorta from cardiac MRI and from stretching tests performed ex-vivo on aorta samples collected during ascending aorta replacement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.