Using transcranial near-infrared spectroscopy (NIRS) to measure changes in the redox state of cerebral cytochrome c oxidase (Δ[oxCCO]) during functional activation in healthy adults is hampered by instrumentation and algorithm issues. This study reports the Δ[oxCCO] response measured in such a setting and investigates possible confounders of this measurement. Continuous frontal lobe NIRS measurements were collected from 11 healthy volunteers during a 6-minute anagram-solving task, using a hybrid optical spectrometer (pHOS) that combines multi-distance frequency and broadband components. Only data sets showing a hemodynamic response consistent with functional activation were interrogated for a Δ[oxCCO] response. Simultaneous systemic monitoring data were also available. Possible influences on the Δ[oxCCO] response were systematically investigated and there was no effect of: 1) wavelength range chosen for fitting the measured attenuation spectra; 2) constant or measured, with the pHOS in real-time, differential pathlength factor; 3) systemic hemodynamic changes during functional activation; 4) changes in optical scattering during functional activation. The Δ[oxCCO] response measured in the presence of functional activation was heterogeneous, with the majority of subjects showing significant increase in oxidation, but others having a decrease. We conclude that the heterogeneity in the Δ[oxCCO] response is physiological and not induced by confounding factors in the measurements.
A technique is presented for the 3D visualisation of the coronary arterial tree using an imaging cryomicrotome. After the coronary circulation of the excised heart was filled with a fluorescent plastic, the heart was frozen and mounted in the cryomicrotome. The heart was then sliced serially, with a slice thickness of 40 microm, and digital images were taken from each cutting plane of the remaining bulk material using appropriate excitation and emission filters. Using maximum intensity projections over a series of images in the cutting plane and perpendicular plane, the structural organisation of intramural vessels was visualised in the present study. The branching end in the smallest visible vessels, which define tissue areas that are well delineated from each other by 1-2 mm wide bands populated only by vessels less than 40 microm in diameter. The technique presented here allows further quantification in the future of the 3D structure of the coronary arterial tree by image analysis techniques.
The redox state of cerebral mitochondrial cytochrome c oxidase monitored with near-infrared spectroscopy (Δ[oxCCO]) is a signal with strong potential as a non-invasive, bedside biomarker of cerebral metabolic status. We hypothesised that the higher mitochondrial density of brain compared to skin and skull would lead to evidence of brain-specificity of the Δ[oxCCO] signal when measured with a multi-distance near-infrared spectroscopy (NIRS) system. Measurements of Δ[oxCCO] as well as of concentration changes in oxygenated (Δ[HbO2]) and deoxygenated haemoglobin (Δ[HHb]) were taken at multiple source-detector distances during systemic hypoxia and hypocapnia (decrease in cerebral oxygen delivery), and hyperoxia and hypercapnia (increase in cerebral oxygen delivery) from 15 adult healthy volunteers. Increasing source-detector spacing is associated with increasing light penetration depth and thus higher sensitivity to cerebral changes. An increase in Δ[oxCCO] was observed during the challenges that increased cerebral oxygen delivery and the opposite was observed when cerebral oxygen delivery decreased. A consistent pattern of statistically significant increasing amplitude of the Δ[oxCCO] response with increasing light penetration depth was observed in all four challenges, a behaviour that was distinctly different from that of the haemoglobin chromophores, which did not show this statistically significant depth gradient. This depth-dependence of the Δ[oxCCO] signal corroborates the notion of higher concentrations of CCO being present in cerebral tissue compared to extracranial components and highlights the value of NIRS-derived Δ[oxCCO] as a brain-specific signal of cerebral metabolism, superior in this aspect to haemoglobin.
Blood flow is distributed through the heart muscle via a system of vessels forming the coronary circulation. The perfusion of the myocardium can be hampered by atherosclerosis creating localized obstructions in the epicardial vessels or by microvascular disease. In early stages of the disease, these impediments to blood flow are offset by dilation of the resistance vessels, which normally compensates for a decrease in perfusion pressure or increased metabolism. However, this dilatory reserve can become exhausted, which in general occurs first at the deeper layers of the heart wall where intramural vessels are subjected to compressive forces related to heart contraction. In the catheterization laboratory, guide wires of 0.33 mm diameter are available that are equipped with a pressure and flow velocity sensor at the tip, which can be positioned distal to the stenosis. These signals provide information about the impediment of the stenosis on coronary flow and allow for the evaluation of the status of the microcirculation. However, the interpretation of these signals is strongly model-dependent and therefore it is of paramount importance to develop realistic models reflecting the anatomy and unique physiology of the coronary circulation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.