With the increased availability of computational resources, the past decade has seen a rise in the use of computational fluid dynamics (CFD) for medical applications. There has been an increase in the application of CFD to attempt to predict the rupture of intracranial aneurysms, however, while many hemodynamic parameters can be obtained from these computations, to date, no consistent methodology for the prediction of the rupture has been identified. One particular challenge to CFD is that many factors contribute to its accuracy; the mesh resolution and spatial/temporal discretization can alone contribute to a variation in accuracy. This failure to identify the importance of these factors and identify a methodology for the prediction of ruptures has limited the acceptance of CFD among physicians for rupture prediction. The International CFD Rupture Challenge 2013 seeks to comment on the sensitivity of these various CFD assumptions to predict the rupture by undertaking a comparison of the rupture and blood-flow predictions from a wide range of independent participants utilizing a range of CFD approaches. Twenty-six groups from 15 countries took part in the challenge. Participants were provided with surface models of two intracranial aneurysms and asked to carry out the corresponding hemodynamics simulations, free to choose their own mesh, solver, and temporal discretization. They were requested to submit velocity and pressure predictions along the centerline and on specified planes. The first phase of the challenge, described in a separate paper, was aimed at predicting which of the two aneurysms had previously ruptured and where the rupture site was located. The second phase, described in this paper, aims to assess the variability of the solutions and the sensitivity to the modeling assumptions. Participants were free to choose boundary conditions in the first phase, whereas they were prescribed in the second phase but all other CFD modeling parameters were not prescribed. In order to compare the computational results of one representative group with experimental results, steady-flow measurements using particle image velocimetry (PIV) were carried out in a silicone model of one of the provided aneurysms. Approximately 80% of the participating groups generated similar results. Both velocity and pressure computations were in good agreement with each other for cycle-averaged and peak-systolic predictions. Most apparent "outliers" (results that stand out of the collective) were observed to have underestimated velocity levels compared to the majority of solutions, but nevertheless identified comparable flow structures. In only two cases, the results deviate by over 35% from the mean solution of all the participants. Results of steady CFD simulations of the representative group and PIV experiments were in good agreement. The study demonstrated that while a range of numerical schemes, mesh resolution, and solvers was used, similar flow predictions were observed in the majority of cases. To further validate the computati...
Image-based hemodynamic simulations to assess the rupture risk or improve the treatment planning of intracranial aneurysms have become popular recently. However, due to strong modeling assumptions and limitations, the acceptance of numerical approaches remains limited. Therefore, validation using experimental methods is mandatory.In this study, a unique compilation of four in-vitro flow measurements (three particle image velocimetry approaches using a standard (PIV), stereoscopic (sPIV), and tomographic (tPIV) setup, as well as a phase-contrast magnetic resonance imaging (PC-MRI) measurement) were compared with a computational fluid dynamics (CFD) simulation. This was carried out in a patient-specific silicone phantom model of an internal carotid artery aneurysm under steady flow conditions. To evaluate differences between each technique, a similarity index (SI) with respect to the velocity vectors and the average velocity magnitude differences among all involved modalities were computed.The qualitative comparison reveals that all techniques are able to provide a reasonable description of the global flow structures. High quantitative agreement in terms of SI and velocity magnitude differences was found between all PIV methods and CFD. However, quantitative differences were observed between PC-MRI and the other techniques. Deeper analysis revealed that the limited resolution of the PC-MRI technique is a major contributor to the experienced differences and leads to a systematic underestimation of overall velocity magnitude levels inside the vessel. This confirms the necessity of using highly resolving flow measurement techniques, such as PIV, in an in-vitro environment to individually verify the validity of the numerically obtained hemodynamic results.
Inter-particle collisions in turbulent flows are of central importance for many engineering applications and environmental processes. For instance, collision and coalescence is the mechanism for warm rain initiation in cumulus clouds, a still poorly understood issue. This work presents measurements of droplet-droplet interactions in a laboratory turbulent flow, allowing reproducibility and control over initial and boundary conditions. The measured two-phase flow reproduces conditions relevant to cumulus clouds. The turbulent flow and the droplet size distribution are well characterized, and independently the collision rate is measured. Two independent experimental approaches for determining the collision rate are compared with each other: (i) a highmagnification shadowgraphy setup is employed, applying a deformation threshold as collision indicator. This technique has been specifically adapted to measure droplet collision probability in dispersed two-phase flows. (ii) Corresponding results are compared for the first time with a particle tracking approach, post-processing high-speed shadowgraphy image sequences. Using the measured turbulence and droplet properties, the turbulent collision kernel can be calculated for comparison. The two independent measurements deliver comparable orders of magnitude for the collision probability, highlighting the quality of the measurement process, even if the comparison between both
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.