Quantitative microbial risk assessment is a useful way to predict the incidence of infection and illness within a community following exposure to pathogens. We used this risk assessment technique to determine the expected number of Salmonella infections and illnesses resulting from a drinking water -wastewater cross-connection incident using data generated from a distribution system simulator study and compared our results to a reported cross-contamination event that occurred in Pineville, Louisiana in 2000. Probabilities of infection and illness were estimated for different exposure scenarios representing different Salmonella concentrations and the characteristic varied attack rates for waterborne Salmonella. Risks of Salmonella infection range from 10% after a 1 day exposure (assuming the lower bound Salmonella concentration) to a 1-log greater risk of infection for all other scenarios, with risks of infection approximately 99% for 30 and 90 day exposure durations.
Biofilms in potable water distribution systems consist of microorganisms that can survive and grow under the low nutrient concentrations commonly found within water distribution systems. This experiment evaluated the ability of an existing biofilm to reduce the number of introduced microorganisms adhered to materials in an aquatic environment. Ductile iron biofilm sampling coupons were separated into two groups, one had existing biofilm (pre-colonized) and the second group of coupons had no biofilm present (control). Biofilm sampling coupons were challenged by suspensions of individual study organisms consisting of Enterococcus faecium, Escherichia coli, or Aeromonas hydrophilia, and a sterile solution (control). Densities of culturable study organisms on control coupons were compared to densities of these same culturable organisms on biofilm pre-colonized coupons. Results demonstrate that drinking water distribution systems may be vulnerable to the development of potentially pathogenic bacteria in biofilm when lines are initially placed in service.Conclusions are that existing biofilm may serve as a barrier to introduced study organisms.Résumé : Les biofilms présents dans les réseaux de distribution d'eau potable comportent des microorganismes qui peuvent survivre et croître sous les faibles concentrations de nutriments généralement retrouvées dans les réseaux de distribution d'eau. La présente expérience évaluait la capacité d'un biofilm existant à réduire le nombre de microorganismes introduits adhérant au matériel dans un environnement aquatique. Des coupons en fonte ductile pour l'échantillonnage de biofilm ont été séparées en deux groupes, un ayant un biofilm existant (pré-colonisé) et l'autre n'ayant aucun biofilm pré-sent (référence). Les coupons d'échantillonnage de biofilm ont été soumises à des suspensions d'organismes individuels à l'étude, soit d'Enterococcus faecium, d'Escherichia coli, ou d'Aeromonas hydrophilia, et d'une solution stérile (référence). Les densités des organismes cultivables étudiés sur les coupons de référence ont été comparées aux densités de ces mêmes organismes cultivables étudiés sur le biofilm des éprouvettes pré-colonisées. Les résultats montrent que les réseaux de distribution d'eau potable peuvent être vulnérables au développement de bactéries potentiellement pathogènes dans le biofilm lorsque les conduites sont mises en service pour la première fois. Les conclusions sont que le biofilm existant peut servir de barrière à la prolifération des organismes étudiés introduits.
The ability of aerosolized disinfectant agents to reach exterior and interior spaces of walls and other difficult to access areas has potential as a remediation technique for contained biological contamination. Bacillus subtilis were evaluated against aerosolized solutions of distilled water (dH 2 O, control), 0.05% chlorine dioxide (ClO 2 ), and 0.6% sodium hypochlorite (NaOCl). Bacillus subtilis endospores were inoculated onto commercially available gypsum board with paper facing. Aerosols generated from a collison nebulizer were directed into a sterile contact chamber housing the inoculated gypsum board for 4, 8, and 12 hour periods. Independent evaluations were conducted of the gypsum board where the organism B. subtilis were exposed to the aerosolized disinfectant. Treatment effects were evaluated through the collection of surface samples before and after exposures. The aerosolized 0.6% sodium hypochlorite solution was the only treatment successful in reducing the total concentration of B. subtilis. Treatment with sodium hypochlorite solution reduced B. subtilis organisms by 1.55-log after 4 h, 1.92-log after 8 h, and 2.50-log after 12 h of exposure, though the difference in log-reduction between exposure periods were not statistically significant.Résumé : La capacité des désinfectants vaporisés à atteindre les surfaces extérieures et intérieures des murs et d'autres zones difficiles d'accès leur confère le potentiel de remédier à une contamination biologique en milieu fermé. Bacillus subtilis a été évalué contre diverses solutions vaporisées d'eau distillée (contrôle), de dioxyde de chlore à 0,05 % (ClO2), et d'hypochlorure de sodium à 0,6 % (NaOCl). Les endospores de B. subtilis ont été inoculés sur des plaques de plâtre cartonnées disponibles sur le marché. Les aérosols générés par un nébuliseur Collison ont été dirigés dans une salle de contact stérile comprenant les plaques de plâtre cartonnées inoculées pour des durées de quatre, huit et douze heures. Des évaluations indépendantes ont été réalisées sur les plaques de plâtre cartonnées où B. subtilis a été exposé au désinfectant vaporisé. Les effets des traitements ont été évalués par la collecte d'échantillons de surface avant et après les expositions. La solution vaporisée d'hypochlorure de sodium à 0,6 % a été le seul traitement ayant réussi à réduire la concentration totale de B. subtilis. Le traitement avec la solution vaporisée d'hypochlorure de sodium a réduit les organismes B. subtilis de 1,55log après 4 heures, de 1,92log après 8 heures et de 2,50log après 12 heures d'exposition, bien que la différence dans la réduction logarithmique entre les périodes d'exposition n'était pas significative statistiquement. Mots-clés : Bacillus subtilis, désinfectant vaporisé, plaque de plâtre cartonnée.[Traduit par la Rédaction]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.