In this work, a method for detecting and correcting errors in Modbus-RTU communications is designed, implemented, and assessed in a smart metering application. This is a low-cost solution for improving communication quality in conventional Modbus-RTU architectures with copper fieldbus. It consists of introducing error detection and correction devices in the network segments most susceptible to errors caused by electromagnetic interference. Experimental validations were conducted and demonstrated the effectiveness of this method for isolating noisy segments in the communication bus, maintaining full compatibility with commercial devices and improving the performance of the entire network.
A new coiled tubing (CT) manufacturing technology was developed and introduced to commercial field operations in 2015. The new technology uses new steels and new heat treatment processes for complete microstructure transformation to produce significantly improved and uniform microstructure and properties along the entire coiled tubing string, including bias welds. Numerous straight and tapered wall thickness CT strings have been commercially deployed and used in various field operations and environments. Information has been collected for CT field performance evaluation of the new technology 125-ksi and 110-ksi minimum yield strength CT grades. Field results show new technology CT performance and utilization far beyond any conventional CT capability and experience. Additionally, testing of CT strings after extensive field use shows significant remaining string life and confirms observations and conclusions from previous extensive laboratory and field testing.
The new CT manufacturing technology also has been extended to produce a new, 95-ksi yield strength CT grade. This new CT grade has significantly better general performance than comparable conventional CT grades. It also has substantially better performance in sour, aqueous H2S-containing environments. Non-sour and sour test results for the new CT grade and comparisons with other CT grades are presented in the paper. Sour fatigue tests were conducted on full-body CT samples after 4-day sour exposure. Sulfide stress cracking and sour fatigue testing in H2S environments show that the new 95-ksi CT grade has much better sour performance than the conventional 90-ksi grade that is currently the highest CT grade regularly used in sour environments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.