We report the formation of solid-state nanopores using a scanning helium ion microscope. The fabrication process offers the advantage of high sample throughput along with fine control over nanopore dimensions, producing single pores with diameters below 4 nm. Electronic noise associated with ion transport through the resultant pores is found to be comparable with levels measured on devices made with the established technique of transmission electron microscope milling. We demonstrate the utility of our nanopores for biomolecular analysis by measuring the passage of double-strand DNA.
Articles you may be interested inAnalysis of subsurface beam spread and its impact on the image resolution of the helium ion microscope Recent investigations are gaining us a better understanding of the nature of the beam-sample interactions in the helium ion microscope and what they mean for the image information provided. In secondary electron ͑SE͒ imaging, for example, the surface sensitivity is attributed to the low SE-II fraction. Voltage contrast imaging shows the ability to see both buried structures and to probe the conductance to ground of surface contacts. It is found, however, that the prominence of these two types of contrast varies oppositely with beam energy, yielding information about the nature of the interactions that gives rise to them. Transmission ion imaging can yield information about material density, atomic number, grain structure, and electronic structure. It is possible to capture the top-side SE signal, bright field signal, and dark field signal from a given sample simultaneously. The detection of diffraction contrast is under investigation.
A 25 keV focused helium ion beam has been used to grow PtC nanopillars on a silicon substrate by beam-induced decomposition of a (CH 3 ) 3 Pt(C P CH 3 ) precursor gas. The ion beam diameter was about 1 nm. The observed relatively high growth rates suggest that electronic excitation is the dominant mechanism in helium ion-beam-induced deposition. Pillars grown at low beam currents are narrow and have sharp tips. For a constant dose, the pillar height decreases with increasing current, pointing to depletion of precursor molecules at the beam impact site. Furthermore, the diameter increases rapidly and the total pillar volume decreases slowly with increasing current.Monte Carlo simulations have been performed with realistic values for the fundamental deposition processes. The simulation results are in good agreement with experimental observations. In particular, they reproduce the current dependences of the vertical and lateral growth rates and of the volumetric deposition efficiency. Furthermore, the simulations reveal that the vertical pillar growth is due to type-1 secondary electrons and primary ions, while the lateral outgrowth is due to type-2 secondary electrons and scattered ions.
Helium ion microscopy is now a demonstrated practical technology that possesses the resolution and beam currents necessary to perform nanofabrication tasks, such as circuit edit applications. Due to helium's electrical properties and sample interaction characteristics relative to gallium, it is likely that the properties and deposition characteristics of beam induced deposited films will be different than those produced using gallium focused ion beam technology. However, there is at this date very little literature discussing the use of helium beams for beam induced chemistry or characterization of the resulting films. In this article, the authors present initial results regarding the deposition of platinum using a helium ion microscope and a gaseous organometallic precursor. Within this work a Carl Zeiss ORION™ helium ion microscope was used along with an OmniGIS unit to deposit platinum while exploring a variety of controllable parameters such as beam current, beam overlap, and size of deposition.
The newly introduced ORION™ helium ion microscope has been used for high resolution imaging and nanofabrication. More recently, an energy sensitive detector has been developed that permits the measurement of the energy spectrum of the backscattered helium ions. The spectra can be analyzed directly or compared with the simulated spectra from hypothetical models of the specimen. The technique can provide information about the elemental composition of the specimen or structural information (for example, layer thickness) of the specimen.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.