The aim of the guideline presented in this article is to unify the test parameters for image quality evaluation and radiation output in all types of cone-beam computed tomography (CBCT) systems. The applications of CBCT spread over dental and interventional radiology, guided surgery and radiotherapy. The chosen tests provide the means to objectively evaluate the performance and monitor the constancy of the imaging chain. Experience from all involved associations has been collected to achieve a consensus that is rigorous and helpful for the practice. The guideline recommends to assess image quality in terms of uniformity, geometrical precision, voxel density values (or Hounsfield units where available), noise, low contrast resolution and spatial resolution measurements. These tests usually require the use of a phantom and evaluation software. Radiation output can be determined with a kerma-area product meter attached to the tube case. Alternatively, a solid state dosimeter attached to the flat panel and a simple geometric relationship can be used to calculate the dose to the isocentre. Summary tables including action levels and recommended frequencies for each test, as well as relevant references, are provided. If the radiation output or image quality deviates from expected values, or exceeds documented action levels for a given system, a more in depth system analysis (using conventional tests) and corrective maintenance work may be required.
Polymeric heart valves could offer an optimum alternative to current prostheses, by joining the advantages of mechanical and bioprosthetic valves. Though a number of materials suitable for this application have recently become available, significant improvements in the valve design are still needed. In this paper, a novel polymeric heart valve design is proposed and its optimization procedure, based on the use of finite elements, is described. The design strategy was aimed at reducing the energy absorbed during the operating cycle, resulting in high hydrodynamic performances and reduced stress levels. The efficacy of the design strategy was assessed by comparing the valve dynamics and stress levels predicted numerically during the cycle with those of an existing and well qualified polymeric valve design. The improved hydrodynamic performance of the proposed design was confirmed experimentally, by in vitro testing in a pulse duplicator.
Almost 3% of people in the Western world will suffer from a venous disease at some time in their lives, but as yet there are very few effective treatments for the venous system. When the valves become incompetent, they allow backflow and subsequent pooling of blood in the lower extremities. Current clinical therapies for the elimination of deep reflux are very invasive and provide short-lasting results. Thus, there is an urgent need for technological evolution of implantable valves and, if possible, with minimally invasive techniques. This review provides a basic history of the discovery of deep vein valves and various designs of prosthetic vein valves that have been evaluated in animal models and clinical studies.
Introduction Imaging is essential for the initial diagnosis and monitoring of the novel coronavirus, which emerged in Wuhan, China. This study aims to assess the insight of radiographers on how the COVID-19 pandemic has affected their work routine and if protective measures are applied. Method A prospective observational study was conducted among radiographers registered in the Cyprus Society of Registered Radiologic Technologists & Radiation Therapy Technologists. A questionnaire composed of 28 multiple choice questions was utilised, and the data analysis was performed using SPSS software with the statistical significance assumed as p-value < 0.05. Results Out of 350 registered radiographers, 101 responses were received. The results showed that there are statistically significant differences regarding the working hours, the feeling of stress, the work effectiveness, the average examination time, the presence of a protocol used among the different workplaces of the participants; a private radiology centre, a private hospital or a public hospital, with a p-value 0.0022, 0.015, 0.027, 0.001, 0.0001 respectively. Also, statistically significant differences were observed in the decontamination methods used for equipment (p-value 0.007), for air (p-value 0.04) and when decontamination takes place (p-value 0.00032) among the different workplaces of the participants. Nonetheless, the majority of radiographers believe that their workplace is sufficiently provided with PPE, cleaning supplies, equipment, and with cleaning personnel and are optimistic regarding the adequacy of these provisions in the next three months. Conclusion This study showed that in the Republic of Cyprus, there are protocols regarding protective measures against COVID-19, and the radiographers are adequately trained on how to face an infectious disease outbreak. However, work is needed in order to develop protocols that reassure the safety of patients and medical personnel while managing the excess workload effectively. Implications for practice This study indicates the importance of applying protective measures and protocols in the radiology departments in order to minimise the spread of the virus.
Background: It is widely accepted that venous valves play an important role in reducing the pressure applied to the veins under dynamic load conditions, such as the act of standing up. This understanding is, however, qualitative and not quantitative. The purpose of this paper is to quantify the pressure shielding effect and its variation with a number of system parameters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.