There are only few data concerning persistence of neutralizing antibodies (NAbs) among SARS-CoV-2-infected healthcare workers (HCW). These individuals are particularly exposed to SARS-CoV-2 infection and at potential risk of reinfection. We followed 26 HCW with mild COVID-19 three weeks (D21), two months (M2) and three months (M3) after the onset of symptoms. All the HCW had anti-receptor binding domain (RBD) IgA at D21, decreasing to 38.5% at M3 (p < 0.0001). Concomitantly a significant decrease in NAb titers was observed between D21 and M2 (p = 0.03) and between D21 and M3 (p < 0.0001). Here, we report that SARS-CoV-2 can elicit a NAb response correlated with anti-RBD antibody levels. However, this neutralizing activity declines, and may even be lost, in association with a decrease in systemic IgA antibody levels, from two months after disease onset. This short-lasting humoral protection supports strong recommendations to maintain infection prevention and control measures in HCW, and suggests that periodic boosts of SARS-CoV-2 vaccination may be required.
Background and Objective. To determine the diagnostic yield of nocturnal oximetry versus polygraphy for the diagnosis and classification of sleep apnea hypopnea syndrome (SAHS). Methods. Prospective study conducted in a university hospital. Subjects with a clinical suspicion of SAHS were included. All of them underwent home polygraphy and oximetry on the same night. A correlation was made between the apnea-hypopnea index (AHI) and the oximetry variables. The variable with the highest diagnostic value was calculated using the area under the curve (AUC), and the best cut-off point for discriminating between patients with SAHS and severe SAHS was identified. Results. One hundred and four subjects were included; 73 were men (70%); mean age was 52 ± 10.1 years; body mass index was 30 ± 4.1, and AHI = 29 ± 23.2/h. A correlation was observed between the AHI and oximetry variables, particularly ODI3 (r = 0.850;
P
<
0.001
) and ODI4 (r = 0.912;
P
<
0.001
). For an AHI ≥ 10/h, the ODI3 had an AUC = 0.941 (95% confidence interval (CI) = 0.899–0.982) and the ODI4, an AUC = 0.984 (95% CI = 0.964–1), with the ODI4 having the best cut-off point (5.4/h). Similarly, for an AHI ≥ 30/h, the ODI4 had an AUC = 0.922 (95% CI = 0.859–0.986), with the best cut-off point being 10.5/h. Conclusion. Nocturnal oximetry is useful for diagnosing and evaluating the severity of SAHS. The ODI4 variable was most closely correlated with AHI for both diagnosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.