BackgroundTo study the reliability and validity of high-resolution peripheral quantitative CT (HR-pQCT) with microCT (μCT) as gold standard in the visual detection of cortical breaks in metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints.MethodsTen cadaveric fingers (10 MCP and 9 PIP joints) were imaged by HR-pQCT and μCT and visually analyzed by two independent readers. Intra- and interreader reliability were evaluated for the presence (yes/no, kappa statistics) and the total number (intraclass correlation coefficient, ICC) of cortical breaks. Sensitivity, specificity, positive and negative predictive value (PPV respectively NPV) of HR-pQCT in detecting cortical breaks were calculated.ResultsWith HR-pQCT, mean 149 cortical breaks were identified and with μCT mean 129 (p < 0.05). Intrareader reliability for the presence of a cortical break per quadrant was 0.52 (95 % CI 0.48–0.56) and 0.71 (95 % CI 0.67–0.75) for HR-pQCT and μCT, respectively, and for the total number of cortical breaks 0.61 (95 % CI 0.49–0.70) and 0.75 (95 % CI 0.68–0.82). Interreader reliability for the presence of a cortical break per quadrant was 0.37 (95 % CI 0.33–0.41) and 0.45 (95 % CI 0.41–0.49) for HR-pQCT and μCT, respectively, and for the number of cortical breaks 0.55 (95 % CI 0.43–0.65) and 0.54 (95 % CI 0.35–0.67). Sensitivity, specificity, PPV and NPV of HR-pQCT were 81.6, 64.0, 81.6, and 64 % respectively.ConclusionCortical breaks were commonly visualized in MCP and PIP joints with HR-pQCT and μCT. Reliability of both HR-pQCT and μCT was fair to moderate. HR-pQCT was highly sensitive to detect cortical breaks with μCT as gold standard.Electronic supplementary materialThe online version of this article (doi:10.1186/s12891-016-1148-y) contains supplementary material, which is available to authorized users.
Small cortical interruptions may be the first sign of an erosion, and more interruptions can be found in patients with rheumatoid arthritis (RA) compared with healthy subjects. First, we compared the number and size of interruptions in patients with RA with healthy subjects using high-resolution peripheral quantitative CT (HR-pQCT). Second, we investigated the association between structural damage and inflammatory markers on conventional radiography (CR) and MRI with interruptions on HR-pQCT. Third, the added value of HR-pQCT over CR and MRI was investigated. The finger joints of 39 patients with RA and 38 healthy subjects were examined through CR, MRI, and HR-pQCT. CRs were scored using the Sharp/Van der Heijde method. MRI images were analyzed for the presence of erosions, bone marrow edema, and synovitis. HR-pQCT images were analyzed for the number, surface area, and volume of interruptions using a semiautomated algorithm. Descriptives were calculated and associations were tested using generalized estimating equations. Significantly more interruptions and both a larger surface area and the volume of interruptions were detected in the metacarpophalangeal joints of patients with RA compared with healthy subjects (median, 2.0, 1.42 mm , and 0.48 mm versus 1.0, 0.69 mm , and 0.23 mm , respectively; all p < 0.01). Findings on CR and MRI were significantly associated with more and larger interruptions on HR-pQCT (prevalence ratios [PRs] ranging from 1.03 to 7.74; all p < 0.01) in all subjects, and were consistent in patients with RA alone. Having RA was significantly associated with more and larger interruptions on HR-pQCT (PRs, 2.33 to 5.39; all p < 0.01), also after adjustment for findings on CR or MRI. More and larger cortical interruptions were found in the finger joints of patients with RA versus healthy subjects, also after adjustment for findings on CR or MRI, implying that HR-pQCT imaging may be of value in addition to CR and MRI for the evaluation of structural damage in patients with RA. © 2018 The Authors. Journal of Bone and Mineral Research Published by Wiley Periodicals Inc.
Objectives The purpose of the study was to prospectively investigate change (repair or progression) in the number, surface area and volume of cortical interruptions, bone density (vBMD) and micro-structural parameters assessed by high-resolution peripheral quantitative computed tomography (HR-pQCT) in finger joints of patients with rheumatoid arthritis (RA) treated with synthetic disease modifying anti-rheumatic drugs (sDMARDs) and/or biologic DMARDs (bDMARDs) over a 1-year follow-up period, and in comparison with healthy subjects (HS). Methods Thirty-two patients with RA (221 joints, 53% on bDMARDs) and 32 HS (117 joints) were assessed at baseline and after 1 year using semi-automatic analysis of HR-pQCT images. Mean changes (group level) and the proportion of joints (joint level) with changes beyond the least significant change were calculated. Results At baseline, 530 interruptions were identified in patients, and 136 in HS. The mean of the interruption parameters did not significantly change in either group Mean vBMD decreased more in patients than in HS (− 4.4 versus − 1.1 mgHA/ cm 3 , respectively). In patients versus HS, proportionally more joints showed repair in interruption volume (6.6% versus 1.7%, respectively) and loss of vBMD (26.7% versus 12.9%, respectively). In patients on sDMARDs versus patients on bDMARDs, proportionally more joints showed progression in the number of interruptions and loss of vBMD (6.1% versus 1.8% and 31.3% versus 17.2%, respectively). Conclusions HR-pQCT is able to quantify bone repair and progression. Cortical interruption-, vBMD-, and micro-structure were impaired in RA, of which vBMD and micro-structure further deteriorated, particularly in patients on sDMARDs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.