This review focuses on cultivation of mammalian cells in a suspended perfusion mode. The major technological limitation in the scaling-up of these systems is the need for robust retention devices to enable perfusion of medium as needed. For this, cell retention techniques available to date are presented, namely, cross-flow filters, hollow fibers, controlled-shear filters, vortex-flow filters, spin-filters, gravity settlers, centrifuges, acoustic settlers, and hydrocyclones. These retention techniques are compared and evaluated for their respective advantages and potential for large-scale utilization in the context of industrial manufacturing processes. This analysis shows certain techniques have a limited range of perfusion rate where they can be implemented (most microfiltration techniques). On the other hand, techniques were identified that have shown high perfusion capacity (centrifuges and spin-filters), or have a good potential for scale-up (acoustic settlers and inclined settlers). The literature clearly shows that reasonable solutions exist to develop large-scale perfusion processes.
A novel high-throughput methodology for the simultaneous optimization of many cell culture media components is presented. The method is based on the media blending approach which has several advantages as it works with ready-to-use media. In particular it allows precise pH and osmolarity adjustments and eliminates the need of concentrated stock solutions, a frequent source of serious solubility issues. In addition, media blending easily generates a large number of new compositions providing a remarkable screening tool. However, media blending designs usually do not provide information on distinct factors or components that are causing the desired improvements. This paper addresses this last point by considering the concentration of individual medium components to fix the experimental design and for the interpretation of the results. The extended blending strategy was used to reshuffle the 20 amino acids in one round of experiments. A small set of 10 media was specifically designed to generate a large number of mixtures. 192 mixtures were then prepared by media blending and tested on a recombinant CHO cell line expressing a monoclonal antibody. A wide range of performances (titers and viable cell density) was achieved from the different mixtures with top titers significantly above our previous results seen with this cell line. In addition, information about major effects of key amino acids on cell densities and titers could be extracted from the experimental results. This demonstrates that the extended blending approach is a powerful experimental tool which allows systematic and simultaneous reshuffling of multiple medium components.
Calorimetry has shown real potential at bench-scale for chemical and biochemical processes. The aim of this work was therefore to scale-up the system by adaptation of a standard commercially available 300-L pilot-scale bioreactor. To achieve this, all heat flows entering or leaving the bioreactor were identified and the necessary instrumentation implemented to enable on-line monitoring and dynamic heat balance estimation. Providing that the signals are sufficiently precise, such a heat balance would enable calculation of the heat released or taken up during an operational (bio)process. Two electrical Wattmeters were developed, the first for determination of the power consumption by the stirrer motor and the second for determination of the power released by an internal calibration heater. Experiments were designed to optimize the temperature controller of the bioreactor such that it was sufficiently rapid so as to enable the heat accumulation terms to be neglected. Further calibration experiments were designed to correlate the measured stirring power to frictional heat losses of the stirrer into the reaction mass. This allows the quantitative measurement of all background heat flows and the on-line quantitative calculation of the (bio)process power. Three test fermentations were then performed with B. sphaericus 1593M, a spore-forming bacterium pathogenic to mosquitoes. A first batch culture was performed on a complex medium, to enable optimization of the calorimeter system. A second batch culture, on defined medium containing three carbon sources, was used to show the fast, accurate response of the heat signal and the ability to perfectly monitor the different growth phases associated with growth on mixed substrates, in particular when carbon sources became depleted. A maximum heat output of 1100 W was measured at the end of the log-phase. A fed-batch culture on the same defined medium was then carried out with the feed rate controlled as a function of the calorimeter signal. A maximum heat output of 2250 W was measured at the end of the first log-phase. This work demonstrates that real-time quantitative calorimetry is not only possible at pilot-scale, but could be readily applied at even larger scales. The technique requires simple, readily available devices for determination of the few necessary heat flows, making it a robust, cost-effective technique for process development and routine monitoring and control of production processes.
This article presents a simple, unstructured mathematical model describing microbial growth in continuous culture limited by a gaseous substrate. The model predicts constant gas conversion rates and a decreasing biomass concentration with increasing dilution rate. It has been found that the parameters influencing growth are primarily the gas transfer rate and the dilution rate. Furthermore, it is shown that, for correct simulation of growth, the influence of gaseous substrate consumption on the effective gas flow through the system has to be taken into account. Continuous cultures of Methanobacterium thermoautotrophicum were performed at three different gassing rates. In addition to the measurement of the rates of biomass production, product formation, and substrate consumption, microbial heat dissipation was assessed using a reaction calorimeter. For the on‐line measurement of the concentration of the growth‐limiting substrate, H2, a specially developed probe has been used. Experimental data from continuous cultures were in good agreement with the model simulations. An increase in gassing rate enhanced gaseous substrate consumption and methane production rates. However, the biomass yield as well as the specific conversion rates remained constant, irrespective of the gassing rate. It was found that growth performance in continuous culture limited by a gaseous substrate is substantially different from “classic” continuous culture in which the limiting substrate is provided by the liquid feed. In this report, the differences between both continuous culture systems are discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.