An estimation error of the scattering coefficient of hemoglobin in the high absorption wavelength range has been observed in optical property calculations of blood-rich tissues. In this study, the relationship between the accuracy of diffuse reflectance measurement in the integrating sphere and calculated scattering coefficient was evaluated with a system to calculate optical properties combined with an integrating sphere setup and the inverse Monte Carlo simulation. Diffuse reflectance was measured with the integrating sphere using a small incident port diameter and optical properties were calculated. As a result, the estimation error of the scattering coefficient was improved by accurate measurement of diffuse reflectance. In the high absorption wavelength range, the accuracy of diffuse reflectance measurement has an effect on the calculated scattering coefficient.
An integrating sphere system has been used to investigate the estimation error in the scattering coefficient for biological tissues. Since the angular distribution of diffusely reflected light from a sample may depend on the sample absorbance, leakage at the entrance port may affect estimates of the scattering coefficient based on measurement of diffuse reflectance. In the present study, the dependence of the angular distribution of the diffusely reflected light on the hemoglobin (Hb) concentration in a sample was investigated. Subsequently, the effect of the entrance port diameter on the error in the scattering coefficient estimated based on diffuse reflectance measurements was evaluated. For a biological tissue phantom, the angular reflectance distribution at a wavelength of 405 nm, at which strong absorption occurred, showed an increasing bias toward specular reflection as the Hb concentration was increased. No such concentration dependence was found at a wavelength of 664 nm, where the absorbance was low. In addition, it was found that the estimation error in the scattering coefficient was reduced for smaller entrance port diameters. Therefore, when attempting to determine the scattering coefficient for strongly absorbing samples, it is necessary to consider both the angular distribution of the diffusely reflected light and the optimal entrance port diameter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.