High-performance polymer microlens arrays were fabricated by means of withdrawing substrates of patterned wettability from a monomer solution. The f-number (f(#)) of formed microlenses was controlled by adjustment of monomer viscosity and surface tension, substrate dipping angle and withdrawal speed, the array fill factor, and the number of dip coats used. An optimum withdrawal speed was identified at which f(#) was minimized and array uniformity was maximized. At this optimum, arrays of f/3.48 microlenses were fabricated with one dip coat with uniformity of better than Deltaf/f +/- 3.8%. Multiple dip coats allowed for production of f/1.38 lens arrays and uniformity of better than Deltaf/f +/-5.9%. Average f(#)s were reproducible to within 3.5%. A model was developed to describe the fluid-transfer process by which monomer solution assembles on the hydrophilic domains. The model agrees well with experimental trends.
Materials formed from micro-and nanoscale particles are of interest because they often exhibit novel optical, electrical, magnetic, chemical, or mechanical properties. In this work, a means of constructing particulate materials using DNA strands to selectively attach micro-and nanoparticles to substrates was demonstrated. Unlike previous schemes, the DNA was anchored covalently to the particles and substrates, rather than through protein intermediaries. Highly reproducible selective attachment of 0.11-0.87 m-diameter particles was achieved, with selective:nonselective binding ratios >20:1. Calculations showed that at most 350 and 4200 DNA strands were involved in the binding of the small and large particles, respectively. Experiments showed that the DNA was bent at an angle, relative to the surfaces of their solid supports.
Microfluidic chips require connections to larger macroscopic components, such as light sources, light detectors, and reagent reservoirs. In this article, we present novel methods for integrating capillaries, optical fibers, and wires with the channels of microfluidic chips. The method consists of forming planar interconnect channels in microfluidic chips and inserting capillaries, optical fibers, or wires into these channels. UV light is manually directed onto the ends of the interconnects using a microscope. UV-curable glue is then allowed to wick to the end of the capillaries, fibers, or wires, where it is cured to form rigid, liquid-tight connections. In a variant of this technique, used with light-guiding capillaries and optical fibers, the UV light is directed into the capillaries or fibers, and the UV-glue is cured by the cone of light emerging from the end of each capillary or fiber. This technique is fully self-aligned, greatly improves both the quality and the manufacturability of the interconnects, and has the potential to enable the fabrication of interconnects in a fully automated fashion. Using these methods, including a semi-automated implementation of the second technique, over 10,000 interconnects have been formed in almost 2000 microfluidic chips made of a variety of rigid materials. The resulting interconnects withstand pressures up to at least 800psi, have unswept volumes estimated to be less than 10 femtoliters, and have dead volumes defined only by the length of the capillary.
We report a means of fabricating hydrophilic domains in a hydrophobic background by lithographically patterning an adhesive hydrophobic layer. Polymer microlenses were fabricated on these substrates by use of a dip-coating technique. Various lens shapes (circular, elliptical, square) were fabricated on a variety of substrates (SiO(2), SiN, GaAs, InP, etc.), ranging in size from 2 to 500 microm in diameter, with fill factors of up to 90%. Plano-convex and double-convex lenses were fabricated, with f-numbers as low as 1.38 and 1.2, respectively. Optimum lens surfaces deviated from spherical by just +/-5 nm . The lenses are stable at room temperature and exhibit minimal degradation after 24 h at 105 degrees C. The transfer of these polymer lenses to an underlying substrate was also demonstrated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.