The physiological function of butyrylcholinesterase (EC 3.1.1.8, BChE) is not clearly understood, but a role was suggested in the fat utilization process, resulting in positive correlation between plasma triglyceride (TG) levels and BChE activity. Consequently we tested the hypothesis that regular intake of betaine, a natural compound intervening in the liver TG metabolism could influence the BChE activity. The BChE activity was estimated spectrophotometrically in plasma of rats fed with betaine enriched standard (B) or high-fat diet (HFB). The results confirmed decreased TG plasma levels after betaine treatment independently on the type of diet (0.15±0.03 (B) vs. 0.27±0.08 (control) mmol/l; p=0.003 and 0.13±0.03 (HFB) vs. 0.27±0.08 (control) mmol/l; p=0.005). The BChE activity increased significantly with betaine administration, however the change was more distinct in the HFB group (0.84±0.34 (HFB) vs. 0.22±0.04 (control) O.D./min/mg; p<0.001 and 0.41±0.11 (B) vs. 0.22±0.04 (control) O.D./min/mg; p=0.001). In conclusion, betaine intake led to elevated BChE activity in plasma and this effect was potentiated by the HF diet. Since betaine is in general used as a supplement in the treatment of liver diseases accompanied by TG overload, its impact on the BChE activity in the role of the liver function marker should be taken into account.
Immunochemical reactions are fast, can be automated, and generally do not require pretreatment of biological material. Based on these advantages, they are widely used. On the other hand, they are susceptible to analytical interference that can lead to inaccurate results. These factors include the presence of anti-mouse antibodies, causing false positive (or sometimes false negative) results. Although the anti-mouse antibodies over many decades have been repeatedly identified to be the causative source but due to the rarity of such encounters they remain insufficiently considered. Here we show a case, a 45 year-old female who was mis-diagnosed with pregnancy due to falsely elevated human chorionic gonadotropin (hCG) due to anti-mouse antibodies. This led to the patient undergoing two ultrasound examinations and laparoscopy before the hCG was repeated on alternative assays which showed negative results, preventing the patient from methotrexate treatment. Here we describe the details of the case, outline the assay principal, supporting the finding from literature and outlining a process on how to identify such interferences in timely manner.
Aim. We present two cases with clearly discrepant results of clinical examination and cardiac troponin I (cTnI) and cardiac troponin T (cTnT) concentrations. In similar cases with discrepant results, the possibility of interference should be considered. Methods. Due to the suspicion of the presence of macrotroponin I in both of the presented cases, the patients were invited to our laboratory and both cTnI (Architect i1000, Abbott) and cTnT (Cobas 8000, Roche) concentrations were analysed. The samples were treated by preincubation in a heterophilic antibodies blocking tube (HBT) and analysed. Precipitation with polyethylene glycol solution (PEG) and molecular weight separation by gel filtration on Sephadex G100 was performed and concentrations of cTnI were analysed. Results. In the same blood sample, the cTnT and cTnI concentrations were 7 and 1782 ng/L, respectively, in Case 1, and 6 and 96 ng/L, respectively, in Case 2. Incubation of samples in HBT had no significant effect. CTnI concentrations after precipitation with PEG -presented as the percentage of initial concentrations -were 7.4% in Case 1 (and 26.8% in the control sample) and 1.4% in Case 2 (and 56.0% in the control sample). These results indicate a significant decrease in both cases, supporting presence of macrotroponin I. Finally, analyses of cTnI concentrations after gel filtration also supported the presence of macrotroponin I. Conclusion.The present cases show that the presence of macrotroponin can lead to unnecessary investigation of the patient. When the possibility of interference is suspected, cooperation with laboratory staff to help with interpretation or to perform more detailed analysis is crucial.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.