A rapid HPLC method was developed for the assay of tocopheryl acetate and ascorbyl tetraisopalmitate in cosmetic formulations. The validated method was applied for quantitative determination of these vitamins in simulated emulsion formulation. Samples were analysed directly on a RP-18 reverse phase column with UV detection at 222 nm. A mixture of methanol and isopropanol (25 : 75 v/v) was used as mobile phase. The retention time of tocopheryl acetate and ascorbyl tetraisopalmitate were 3.0 min and 5.9 min, respectively. Recovery was between 95% and 104%. In addition, the excipients did not interfere in the analysis. The method is simple, reproducible, selective and is suitable for routine analyses of commercial products.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.