The article assesses the strength and structural parameters of load-bearing layers of metal biobearings made of CoCrMo alloy. The research material consisted of unicompartmental knee joint endoprostheses used in the human body, removed due to excessive wear. No patient participated in the examinations. The endoprostheses used as research material underwent the liquidation procedures in the hospital, which has all necessary permissions and certifications to perform endoprosthetic procedures. Endoprostheses selected for the examinations had been used for 6 to 12 years at similar load conditions as declared by the patients, i.e., body weight of F = 835 N, declared activity expressed as the number of load cycles up to 100 thousand/year, and no artificial joint infections. To assess the homogeneity of the research material, the analysis of chemical composition using a Joel scanning electron microscope with EDS (Energy-dispersive X-ray spectroscopy) was made to exclude endoprostheses with various alloying additives. Microscopic examinations were performed using the Phenom XL microscope, while the wear surface was examined using a Keyence VHX-900F microscope. Several experimental tests were also carried out on load-bearing surfaces to assess changes in strength parameters of the base material after a known life cycle and load conditions. Material hardness using the Vickers method, yield point, critical value of stress intensity coefficient, and the coefficient of friction µ were evaluated. The examinations allowed for the systematization of wear in the knee and femoral components of unicompartmental hip endoprostheses. The statistical evaluation of the number and costs of hip joint replacement surgeries in Poland was also made.
This paper presents the results of research on the determination of the influence of kinetic asymmetry of work rolls on structural changes in hot-rolled bimetallic sheet metals. The tests were conducted on bimetallic samples composed of materials 10CrMo9-10 + X2CrNiMo17-12-2. The scope of the research included a comparative analysis for two cooling variants: I in water (freezing the structure immediately after rolling) and II for cooling in air. The research conducted showed that the introduction of asymmetric conditions to the rolling process results in a greater grain fragmentation in the so-called hard layer and does not have a negative effect on microstructural changes in the soft layer.
. Literature provides three basic methods of explosive cladding, developed by Darenport and Person. Welding trials were performed in two- and three-layer arrangements, where in the second case, copper plates were welded with plates made from aluminium alloys with an interlayer of pure aluminium. Explosive welding technology does not always allow for joining of sheets of specific thicknesses. In order to obtain such thickness, they need to be rolled. The paper presents results of numerical study of asymmetrical rolling process of multilayer plates M1E-Al99.8-AlMg5. Numerical modeling of rolling of multilayer plates was realized by means of Forge 2D program that is based on finite element method. Obtained research results enabled to elucidate the process of rolling of multilayer plates.
The influence of dynamic loads resulting from human motor activity and electrocorrosion inside the human body on the strength parameters of artificial joint elements has not yet been investigated. Hip joint arthroplasty is the most common surgical procedure in the world that allows doctors to remove pain and restore motor skills in people with severe hip diseases, after accidents, and in the elderly. Based on the reports, this article assesses changes in the number of implanted endoprostheses in the years 2005–2019 and determines the trends and estimated changes in the number of implanted hip prostheses in the following decades. The study assesses changes in selected strength parameters of UHMW-PE polyethylene inserts of hip joint endoprostheses during their use in the human body. The research was carried out on appropriately collected samples from UHMW-PE cups removed from the human body with a known history and lifetime from 4 to 10 years. Patients’ body weight ranged from 735 [N] to 820 [N], and the declared physical activity was similar in the entire research group. As part of the research, the values of changes in dynamic modules and the mechanical loss coefficient were determined in relation to the share of the crystalline and amorphous phases of artificial UHMW-PE cups, removed from the human body after different periods of exploitation under similar operating conditions. The analysis of selected strength parameters was performed at a temperature of 40 °C, which corresponds to the working conditions inside the human body. On the basis of numerical studies, the influence of changes in material parameters on the deformation of the artificial acetabulum during the patient’s motor activity, which is one of the causes of fatigue destruction, was determined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.