The authors investigated the classification of regions of interest (ROI's) on mammograms as either mass or normal tissue using a convolution neural network (CNN). A CNN is a backpropagation neural network with two-dimensional (2-D) weight kernels that operate on images. A generalized, fast and stable implementation of the CNN was developed. The input images to the CNN were obtained from the ROI's using two techniques. The first technique employed averaging and subsampling. The second technique employed texture feature extraction methods applied to small subregions inside the ROI. Features computed over different subregions were arranged as texture images, which were subsequently used as CNN inputs. The effects of CNN architecture and texture feature parameters on classification accuracy were studied. Receiver operating characteristic (ROC) methodology was used to evaluate the classification accuracy. A data set consisting of 168 ROIs containing biopsy-proven masses and 504 ROI's containing normal breast tissue was extracted from 168 mammograms by radiologists experienced in mammography. This data set was used for training and testing the CNN. With the best combination of CNN architecture and texture feature parameters, the area under the test ROC curve reached 0.87, which corresponded to a true-positive fraction of 90% at a false positive fraction of 31%. The authors' results demonstrate the feasibility of using a CNN for classification of masses and normal tissue on mammograms.
We studied the effectiveness of using texture features derived from spatial grey level dependence (SGLD) matrices for classification of masses and normal breast tissue on mammograms. One hundred and sixty-eight regions of interest (ROIS) containing biopsy-proven masses and 504 ROIS containing normal breast tissue were extracted from digitized mammograms for this study. Eight features were calculated for each ROI. The importance of each feature in distinguishing masses from normal tissue was determined by stepwise linear discriminant analysis. Receiver operating characteristic (ROC) methodology was used to evaluate the classification accuracy. We investigated the dependence of classification accuracy on the input features, and on the pixel distance and bit depth in the construction of the SGLD matrices. It was found that five of the texture features were important for the classification. The dependence of classification accuracy on distance and bit depth was weak for distances greater than 12 pixels and bit depths greater than seven bits. By randomly and equally dividing the data set into two groups, the classifier was trained and tested on independent data sets. The classifier achieved an average area under the ROC curve, Az, of 0.84 during training and 0.82 during testing. The results demonstrate the feasibility of using linear discriminant analysis in the texture feature space for classification of true and false detections of masses on mammograms in a computer-aided diagnosis scheme.
Presents a novel approach for segmentation of suspicious mass regions in digitized mammograms using a new adaptive density-weighted contrast enhancement (DWCE) filter in conjunction with Laplacian-Gaussian (LG) edge detection. The DWCE enhances structures within the digitized mammogram so that a simple edge detection algorithm can be used to define the boundaries of the objects. Once the object boundaries are known, morphological features are extracted and used by a classification algorithm to differentiate regions within the image. This paper introduces the DWCE algorithm and presents results of a preliminary study based on 25 digitized mammograms with biopsy proven masses. It also compares morphological feature classification based on sequential thresholding, linear discriminant analysis, and neural network classifiers for reduction of false-positive detections.
This paper presents segmentation and classification results of an automated algorithm for the detection of breast masses on digitized mammograms. Potential mass regions were first identified using density-weighted contrast enhancement (DWCE) segmentation applied to single-view mammograms. Once the potential mass regions had been identified, multiresolution texture features extracted from wavelet coefficients were calculated, and linear discriminant analysis (LDA) was used to classify the regions as breast masses or normal tissue. In this article the overall detection results for two independent sets of 84 mammograms used alternately for training and test were evaluated by free-response receiver operating characteristics (FROC) analysis. The test results indicate that this new algorithm produced approximately 4.4 false positive per image at a true positive detection rate of 90% and 2.3 false positives per image at a true positive rate of 80%.
We investigated the application of multiresolution global and local texture features to reduce false-positive detection in a computerized mass detection program. One hundred and sixty-eight digitized mammograms were randomly and equally divided into training and test groups. From these mammograms, two datasets were formed. The first dataset (manual) contained four regions of interest (ROIs) selected manually from each of the mammograms. One of the four ROIs contained a biopsy-proven mass and the other three contained normal parenchyma, including dense, mixed dense/fatty, and fatty tissues. The second dataset (hybrid) contained the manually extracted mass ROIs, along with normal tissue ROIs extracted by an automated Density-Weighted Contrast Enhancement (DWCE) algorithm as false-positive detections. A wavelet transform was used to decompose an ROI into several scales. Global texture features were derived from the low-pass coefficients in the wavelet transformed images. Local texture features were calculated from the suspicious object and the peripheral subregions. Linear discriminant models using effective features selected from the global, local, or combined feature spaces were established to maximize the separation between masses and normal tissue. Receiver Operating Characteristic (ROC) analysis was conducted to evaluate the classifier performance. The classification accuracy using global features were comparable to that using local features. With both global and local features, the average area, Az, under the test ROC curve, reached 0.92 for the manual dataset and 0.96 for the hybrid dataset, demonstrating statistically significant improvement over those obtained with global or local features alone. The results indicated the effectiveness of the combined global and local features in the classification of masses and normal tissue for false-positive reduction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.