A healthy 32-year-old G3P3 woman with an unknown last menstrual period presented to the emergency department with intense abdominal pain and pain in the right chest that radiated down the right arm. Further workup showed that she had a ruptured ectopic pregnancy with significant haemoperitoneum. After successful laparoscopic evacuation of the ectopic pregnancy and haemoperitoneum, the patient subsequently developed a right ovarian vein thrombosis 4 weeks after the procedure. She was treated with anticoagulation, and further haematological studies did not show any significant findings. Postpartum ovarian vein thrombosis is extremely rare and can be life- threatening if not accurately diagnosed and treated with anticoagulation or surgical management in a timely manner.
Background: Unstable fractures of the base of the middle phalanx are notorious for causing chronic loss of proximal interphalangeal (PIP) joint function, and they remain a challenge for the hand surgeon. We report on a temporary intraoperatively constructed internal joint stabilizer for unstable PIP joint injuries. Methods: Across 2 institutions, a retrospective chart review was performed for cases with acute presentation of pilon fracture or fracture-dislocation of the base of the middle phalanx which were surgically treated with an internal joint stabilizer. Information collected included time from injury to surgical intervention, time from implantation to device removal, complications, and preoperative and postoperative range of motion. Results: Seven patients met the inclusion criteria with a mean age of 51 (range: 24-72) years and a mean follow-up of 29 (range: 11-72) months. After removal of the fixator, the mean arc of PIP joint motion was 8° to 88° (range: 0°-100°). There were no infections, no hardware loosening or failures, and no revision procedures. Conclusion: The current findings are comparable to the results for dynamic external fixators. An internal joint stabilizer for unstable injuries to the base of the middle phalanx provides satisfactory functional outcomes, allows early postoperative motion, and mitigates the routine complications which may arise with external fixation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.