In the dog of this report, vitamin D-dependent rickets type I and suspected nutritional secondary hyperparathyroidism developed following intake of a nutritionally incomplete and unbalanced diet. The raw meat-based, home-prepared diet fed to the dog was not feed-trial tested for any life stage by the Association of American Feed Control Officials, and its gross nutrient imbalance induced severe metabolic, orthopedic, and neurologic abnormalities. Inadvertent malnutrition can be avoided through proper diet assessment and by matching nutrient profiles with patients' nutritional needs.
This paper presents the drop test reliability of 0.5mm pitch lead-free chip scale packages (CSPs). Fifteen 0.5mm pitch CSPs were assembled on a standard JEDEC drop reliability test board with Sn3.0Ag0.5Cu lead-free solder. Eight boards were edge-bonded with a UV-cured acrylic; eight boards were edgebonded with a thermal-cured epoxy; and twelve boards were assembled without edge bonding. Half of the edge-bonded test boards were subjected to drop tests at a peak acceleration of 1500G with a pulse duration of 0.5ms, and the other half subjected to drop tests at a peak acceleration of 2900G with a pulse duration of 0.3ms. Half of the test boards without edge bonding were subjected to drop tests at a peak acceleration of 900G with a pulse duration of 0.7ms, and the other half subjected to drop tests at a peak acceleration of 1500G with a pulse duration of 0.5ms. Two drop test failure detection systems were used in this study to monitor the failure of solder joints: a high-speed resistance measurement system and a post-drop static resistance measurement system. The high-speed resistance measurement system, which has a scan frequency of 50KHz and a 16-bit signal width, is able to detect intermittent failures during the short drop impact duration. Statistics of the number of drops to failure for the 15 component locations on each test board are reported. The effect of component position on drop test reliability is discussed. The test results show that the drop test performance of edge-bonded CSPs is five to eight times better than the CSPs without edge bonding. However, the drop test reliability of edge-bonded CSPs with the thermal-cured epoxy is different from that with edge-bonded CSPs with the UV-cured acrylic. The solder crack location and crack area are characterized with the dye penetrant method. The fracture surfaces are studied using scanning electron microscopy (SEM).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.