With poliovirus eradication nearing, few pockets of active wild poliovirus (WPV) transmission remain in the world. Intratypic differentiation (ITD) plays a crucial part in laboratory surveillance as the molecular detection method that can identify and distinguish wild and vaccine-like polioviruses isolated from acute flaccid paralysis cases or environmental sources. The need to detect new variants of WPV serotype 1 (WPV1) and the containment of all serotype 2 polioviruses (PV2) in 2015 required changes to the previous version of the method. The ITD version 5.0 is a set of six real-time reverse transcription-PCR (rRT-PCR) assays that serve as accurate diagnostic tools to easily detect and differentiate PV serotypes and genotypes. We describe the creation and properties of quantitation standards, including 16 control RNA transcripts and nine plaque-isolated viruses. All ITD rRT-PCR assays were validated using these standards, and the limits of detection were determined for each assay. We designed and pilot tested two new assays targeting recently circulating WPV1 genotypes and all PV2 viruses. The WPV1 assay had 99.1% specificity and 100% sensitivity, and the PV2 assay had 97.7% specificity and 92% sensitivity. Before proceeding to the next step in the global poliovirus eradication program, we needed to gain a better understanding of the performance of the ITD 5.0 suite of molecular assays and their limits of detection and specificities. The findings and conclusions in this evaluation serve as building blocks for future development work.
We have identified circulation of 3 genogroups of enterovirus (EV) A71 in India. A new genogroup (proposed designation G) was discovered during this study. We isolated genogroups D and G in wide geographic areas but detected subgenogroup C1 only in 1 focus in western India. A systematic nationwide search for EV-A71 is warranted.
Surveillance and detection of polioviruses (PV) remain crucial to monitoring eradication progress. Intratypic differentiation (ITD) using the real-time RT-PCR kit is key to the surveillance workflow, where viruses are screened after cell culture isolation before a subset are verified by sequencing. The ITD kit is a series of real-time RT-PCR assays that screens cytopathic effect (CPE)-positive cell cultures using the standard WHO method for virus isolation. Because ITD screening is a critical procedure in the poliovirus identification workflow, validation of performance of real-time PCR platforms is a core requirement for the detection of poliovirus using the ITD kit. In addition, the continual update and improvement of the ITD assays to simplify interpretation in all platforms is necessary to ensure that all real-time machines are capable of detecting positive real-time signals. Four platforms (ABI7500 real-time systems, Bio-Rad CFX96, Stratagene MX3000P, and the Qiagen Rotor-Gene Q) were validated with the ITD kit and a redesigned poliovirus probe. The poliovirus probe in the real-time RT-PCR pan-poliovirus (PanPV) assay was re-designed with a double-quencher (Zen™) to reduce background fluorescence and potential false negatives. The updated PanPV probe was evaluated with a panel consisting of 184 polioviruses and non-polio enteroviruses. To further validate the updated PanPV probe, the new assay was pilot tested in five Global Polio Laboratory Network (GPLN) laboratories (Madagascar, India, Philippines, Pakistan, and Democratic Republic of Congo). The updated PanPV probe performance was shown to reduce background fluorescence and decrease the number of false positives compared to the standard PanPV probe.
Background A newly developed bovine-human reassortant pentavalent vaccine (BRV-PV, ROTASIIL®) was tested for its potential effect on the immunogenicity of concomitantly administered EPI vaccines in infants in a randomized controlled study in India. Methods In this Phase III, multicenter, open label, randomized, controlled study, three doses of BRV-PV or two doses of Rotarix® and one dose of placebo were given to healthy infants at 6, 10, and 14 weeks of age. Subjects also received three doses of DTwP-HepB-Hib (diphtheria, tetanus, whole-cell pertussis, hepatitis B, and haemophilus influenzae type b conjugate – pentavalent vaccine) and oral polio vaccine concomitantly at 6, 10, and 14 weeks of age and a single dose of inactivated polio vaccine at 14 weeks of age. Blood samples were collected four weeks after the final vaccination to assess immune responses to all the vaccines administered. For diphtheria, tetanus, hepatitis B, Hib, polio type 1, and polio type 3 antibodies, non-interference was to be supported if the lower limit of the two-sided 90% confidence interval (CI) for the seroprotection rate difference for the BRV-PV group minus the Rotarix® group was >10.0%. For pertussis antibodies, non-interference was to be supported if the lower limit of the two-sided 90% CI for the ratio of geometric mean concentrations (GMCs) was >0.5. Results A total of 1500 infants were randomized to either BRV-PV (1125 infants) or Rotarix® (375 infants), of which 1341 completed the study as per the protocol. More than 97% of subjects achieved seroprotective antibody titres against diphtheria, tetanus, hepatitis B, Hib, polio type 1, and polio type 3 in both groups. The difference in seroprotection rates between the BRV-PV group and the Rotarix® group for all these antibodies was less than 1%. The ratio of GMCs of anti-pertussis IgG concentrations for the BRV-PV group versus Rotarix® was 1.04 [90% CI: 0.90; 1.19]. Conclusion BRV-PV does not interfere with the immunogenicity of concomitantly administered routine infants vaccines.
Background & objectives: Since its first recognition in Wuhan, China, in December 2019, the SARS-CoV-2 has spread rapidly across the world. Though SARS-CoV-2 spreads mainly via the droplets of respiratory secretions, it was also detected in stool samples of patients, indicating active infection of the gastrointestinal tract. Presence of SARS-CoV-2 RNA in sewage samples was reported in February 2020, raising the possibility of using environmental water surveillance to monitor SARS-CoV-2 activity in infected areas. The aim of this study was to standardize the methodology for detection of SARS-CoV-2 from sewage and explore the feasibility of establishing supplementary surveillance for COVID-19. Methods: Sewage specimens were collected from six sites in Mumbai, India, using the grab sample method and processed using polyethylene glycol (PEG)-dextran phase separation method for virus concentration. Real-time reverse transcription-polymerase chain reaction (RT-PCR) assay was used to detect the presence of SARS-CoV-2 RNA. Results: A total of 20 sewage samples collected from six different wards in Mumbai city, before the spread of SARS-CoV-2 infections and during May 11-22, 2020, were processed using the phase separation method. The WHO two-phase PEG-dextran method was modified during standardization. SARS-CoV-2 was found to concentrate in the middle phase only. All samples collected before March 16, 2020 were SARS-CoV-2 negative. Viral RNA was detected in sewage samples collected during the ongoing COVID-19 pandemic in all the six wards. Interpretation & conclusions: PEG-dextran phase separation method was effectively used to concentrate SARS-CoV-2 from domestic waste waters to detection levels. It would be feasible to initiate sewage surveillance for SARS-CoV-2 to generate data about the viral transmission in various epidemiologic settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.