This article presents the hardware implementation and a behavioral model-based RF system modeling and simulation (M&S) study of compressive sensing (CS) based 2D angle-of-arrival (AoA) measurement system for 2–18 GHz radar electronic support measures (RESM). A 6-channel ultra-wideband RF digital receiver was first developed using a PXIe-based multi-channel digital receiver paired with a 6-element random-spaced 2D cavity-backed-spiral-antenna array. Then the system was tested in an open lab environment. The measurement results showed that the system can measure AoA of impinging signals from 2–18 (GHz) with overall RMSE of estimation at 3.60, 2.74, 1.16, 0.67 and 0.56 (deg) in L, S, C, X and Ku bands, respectively. After that, using the RF high-fidelity M&S (RF HF-M&S) approach, a 6-channel AoA measurement system behavioral model was also developed and studied using a radar electronic warfare (REW) engagement scenario. The simulation result showed that the airborne AoA measurement system could successfully measure an S-band ground-based target acquisition radar signal in the dynamic REW environment. Using the RF HF-M&S model, the applicability of the system in other frequencies within 2–18 (GHz) was also studied. The simulation results demonstrated that the airborne AoA measurement system can be used for 2–18 GHz RESM applications.
It is always an interesting research topic for digital receiver (DRX) designers to develop a DRX with (1) ultrawide instantaneous bandwidth (IBW), (2) high sensitivity, (3) fine time-of-arrival-measurement resolution (TMR), and (4) fine frequency-measurement resolution (FMR) for weak signal detection. This is because designers always want their receivers to have the widest possible IBW to detect far away and/or weak signals. As the analog-to-digital converter (ADC) rate increasing, the modern DRX IBW increases continuously. To improve the signal detection based on blocking FFT (BFFT) method, this paper introduces the new concept of accumulatively increasing receiver sensitivity (AIRS) for DRX design. In AIRS, a very large number of frequency-bins can be used for a given IBW in the time-to-frequency transform (TTFT), and the DRX sensitivity is cumulatively increased, when more samples are available from high-speed ADC. Unlike traditional FFT-based TTFT, the AIRS can have both fine TMR and fine FMR simultaneously. It also inherits all the merits of the BFFT, which can be implemented in an embedded system. This study shows that AIRS-based DRX is more efficient than normal FFT-based DRX in terms of using time-domain samples. For example, with a probability of false alarm rate of for frequency-bins with TMR = 50 nSec, FMR = 2.4414 KHz, IBW > 1 GHz and ADC rate at 2.56 GHz, AIRS-based DRX detects narrow-band signals at about −42 dB of input signal-to-noise ratio (Input-SNR), and just uses a little less than real-samples. However, FFT-based DRX have to use all samples. Simulation results also show that AIRS-based DRX can detect frequency-modulated continuous wave signals with 0.1, 1, 10 and 100 MHz bandwidths at about −39.4, −35.1, −30.2, and −25.5 dB of Input-SNR using about 264.6 K, 104.7 K, 40.2 K and 18.3 K real-samples, respectively, in frequency-bins for TTFT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.