The radiation exposure dose must be optimised because the hazard resulting from an interventional radiology procedure is long term depending on the patient. The aim of this study was to measure the radiation doses received by the patients and medical staff during endoscopic retrograde cholangiopancreatography (ERCP) procedures. Data were collected during 126 ERCP procedures, including the dose-area product (DAP), entrance dose (ED), effective dose (E), fluoroscopy time (T) and number of digital radiographs (F). The medical staff members each wore a personal thermoluminescence dosemeter to monitor exposure during ERCP procedures. The mean DAP, ED, E and T were 47.06 Gy cm(2), 196.06 mGy, 8.93 mSv, 7.65 min and 9.21 images, respectively. The mean dose to the staff was 0.175 mSv and that to the assistant was 0.069 mSv. The dose to the medical staff was minimal when appropriate protective measures were used. The large variation in the patient doses must be further investigated.
Digital radiography is often performed at a higher dose rate than analogue radiography for image acquisition. The authors measured the Entrance Surface Dose (ESD) of analogue and digital radiography techniques for 14 radiographic examinations from randomly selected medical centres in the central district of Korea. It was that the mean ESD of the digital examinations was 2.84 mGy (range, 0.37-6.38 mGy) and that of the analogue examinations was 1.83 mGy (range, 0.38-4.74 mGy), resulting in a 55.25 % higher ESD for digital technique. Although this survey is not completely representative of Korea, findings of this study indicate a need for closer exposure management in digital radiography to minimise patient dose.
Radiation dose monitoring in medical imaging examination areas is mandatory for the reduction of patient radiation exposure. Recently, dose monitoring techniques that use digital imaging and communications in medicine (DICOM) dose structured reports (SR) have been introduced. The present paper discusses the setup of a radiation dose monitoring system based on DICOM data from university hospitals in Korea. This system utilizes the radiation dose data-archiving method of standard DICOM dose SR combined with a DICOM modality performed procedure step (MPPS). The analysis of dose data based on a method utilizing DICOM tag information is proposed herein. This method supports the display of dose data from non-dosimeter-attached X-ray equipment. This system tracks data from 62 pieces of equipment to analyze digital radiographic, mammographic, mobile radiographic, CT, PET-CT, angiographic, and fluorographic modalities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.