Diisopropylfluorophosphate (DFP) is a potent acetylcholinesterase inhibitor commonly used in toxicological studies as an organophosphorus nerve agent surrogate. However, LD50 values for DFP in the same species can differ widely even within the same laboratory, possibly due to the use of degraded DFP. The objectives here were to identify an efficient synthesis route for high purity DFP and assess the storage stability of both the in-house synthesized and commercial source of DFP at the manufacturer-recommended storage temperature of 4°C, as well as −10°C and −80°C. After 393 days, the commercial DFP stored at 4°C experienced significant degradation, while only minor degradation was observed at −10°C and none was observed at −80°C. DFP prepared using the newly identified synthesis route was significantly more stable, exhibiting only minor degradation at 4°C and none at −10°C or −80°C. The major degradation product was the monoacid derivative diisopropylphosphate, formed via hydrolysis of DFP. It was also found that storing DFP in glass containers may accelerate the degradation process by generating water in situ as hydrolytically generated hydrofluoric acid attacks the silica in the glass. Based on the results here, it is recommended that DFP be stored at or below −10°C, preferably in air-tight, nonglass containers.
Online, droplet-based in-source chemical derivatization is accomplished using a coaxial-flow contained-electrospray ionization (contained-ESI) source to enhance sensitivity for the mass spectrometric analysis of saccharides. Derivatization is completed in microseconds by exploiting the reaction rate acceleration afforded by electrospray microdroplets. Significant improvements in method sensitivity are realized with minimal sample preparation and few resources when compared to traditional benchtop derivatizations. For this work, the formation of easily ionizable phenylboronate ester derivatives of several mono-, di-, and oligosaccharides is achieved. Various reaction parameters including concentration and pH were evaluated, and a Design of Experiments approach was used to optimize ion source parameters. Signal enhancements of greater than two orders of magnitude were observed for many mono-and disaccharides using in-source phenylboronic acid derivatization, resulting in partsper-trillion (picomolar) limits of detection. In addition, amino sugars such as glucosamine, which do not ionize in negative mode, were detected at low parts-per-billion concentrations, and isobaric sugars such as lactose and sucrose were easily distinguished. The new in-source derivatization approach can be employed to expand the utility of ESI-MS analysis for compounds that historically experience limited sensitivity and detectability, while avoiding resource-intensive, bulk-phase derivatization procedures.
Dry-state microsampling techniques are convenient and advantageous for sample collection in resource-limited settings, including healthcare systems designed for the underserved population. In this work, a microsampling platform based on an embossed hydrophobic paper substrate is introduced together with three-dimensional (3D) printed cartridges that offer opportunities for rapid (<30 min) drying of the collected samples while also preserving sample integrity when the embossed paper chip is shipped at room temperature. More importantly, a new pinhole paper spray ionization method was developed that facilitates direct mass spectrometry (MS) analysis of the dried blood samples without prior sample preparation. We compared the direct pinhole paper spray MS method with a liquid chromatographic (LC) MS approach that relied upon electrospray ionization (ESI) after analytes present in the blood sample were extracted through liquid–liquid extraction. Limits of detection as low as 0.12 and 0.49 ng/mL were calculated for cocaine and its metabolite benzoylecgonine, respectively, when using the direct pinhole paper spray MS method. Analytical merits such as precision and accuracy, recovery, carryover effects, and analyte stability were all quantified for this new paper spray method and compared to the traditional LC-ESI-MS. Although LC-ESI-MS was observed to be 10× more sensitive, the linear dynamic range for both methods was determined to be the same, in the range of 1–500 ng/mL for both cocaine and benzoylecgonine analytes. When fully developed, the current microsampling strategy could offer an easy-to-use kit that can enable a more effective MS analysis of 20 μL dried blood samples delivered by mail. Both sensitivity (10×) and sample stability are found to be more superior for blood prepared in the embossed hydrophobic paper compared to samples prepared in the planar hydrophilic paper.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.