A new solid-wall vascular graft which has a compliance approximating that of the natural artery has been prepared from a copolyether-urethane material. Six of nine of these compliant grafts implanted in dogs were patent on removal, the longest implant time being 77 days for a 4-mm I.D. femoral artery graft. This is in contrast to noncompliant grafts of the same copolyurethane in which failure usually occurred within 48 hr.
Recent animal and human studies have suggested that positive indium 111-labeled leukocyte scans may help establish the diagnosis of vascular graft infection; however, there is little information available about the predictive value of both positive and negative leukocyte scans in larger groups of patients. In this study 31 indium 111 leukocyte scans were performed prior to definitive treatment in 21 patients with suspected vascular graft infections. Patients with more than one leukocyte scan performed had either anatomically distinct sites of infection or rescanning of a potentially infected site after definitive treatment. Scans were performed according to the method of Baker et al., attaching 500 muCi of indium 111 to leukocytes with imaging 24 hours later. All patients with positive scans underwent surgical exploration of the area of leukocyte accumulation, with documentation of purulence and culture of the graft. Patients with negative scans were treated as if scan results were indeterminate and underwent surgical exploration for usual clinical indications; if no exploration was performed, the patient was followed up closely for at least 1 year. Twelve of 12 positive scans showed purulence or culture evidence of infection with three different organisms; in 15 instances of negative scans, two operations were performed with one infection noted, whereas no patient without surgery has had a graft infection at 10 months follow-up. In addition to localizing graft infections, two scans demonstrated a nonvascular site of infection. Positive scans also helped determine the extent of infection along the graft, allowing better planning of the surgical procedure. These results indicate that indium 111-labeled leukocyte scans help document and localize prosthetic vascular graft infections.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.