Background Magnetic resonance imaging (MRI) is avoided in most patients with implanted cardiac devices because of safety concerns. Objective To define the safety of a protocol for MRI at the commonly used magnetic strength of 1.5 T in patients with implanted cardiac devices. Design Prospective nonrandomized trial. (ClinicalTrials.gov registration number: NCT01130896) Setting One center in the United States (94% of examinations) and one in Israel. Patients 438 patients with devices (54% with pacemakers and 46% with defibrillators) who underwent 555 MRI studies. Intervention Pacing mode was changed to asynchronous for pacemaker-dependent patients and to demand for others. Tachy-arrhythmia functions were disabled. Blood pressure, electrocardiography, oximetry, and symptoms were monitored by a nurse with experience in cardiac life support and device programming who had immediate backup from an electrophysiologist. Measurements Activation or inhibition of pacing, symptoms, and device variables. Results In 3 patients (0.7% [95% CI, 0% to 1.5%]), the device reverted to a transient back-up programming mode without long-term effects. Right ventricular (RV) sensing (median change, 0 mV [interquartile range {IQR}, −0.7 to 0 V]) and atrial and right and left ventricular lead impedances (median change, −2 Ω[IQR, −13 to 0 Ω], −4 Ω [IQR, −16 to 0 Ω], and −11 Ω [IQR, −40 to 0 Ω], respectively) were reduced immediately after MRI. At long-term follow-up (61% of patients), decreased RV sensing (median, 0 mV, [IQR, −1.1 to 0.3 mV]), decreased RV lead impedance (median, −3 Ω, [IQR, −29 to 15 Ω]), increased RV capture threshold (median, 0 V, IQR, [0 to 0.2 Ω]), and decreased battery voltage (median, −0.01 V, IQR, −0.04 to 0 V) were noted. The observed changes did not require device revision or reprogramming. Limitations Not all available cardiac devices have been tested. Long-term in-person or telephone follow-up was unavailable in 43 patients (10%), and some data were missing. Those with missing long-term capture threshold data had higher baseline right atrial and right ventricular capture thresholds and were more likely to have undergone thoracic imaging. Defibrillation threshold testing and random assignment to a control group were not performed. Conclusion With appropriate precautions, MRI can be done safely in patients with selected cardiac devices. Because changes in device variables and programming may occur, electrophysiologic monitoring during MRI is essential. Primary Funding Source National Institutes of Health.
OBJECTIVE Thalamotomy of the ventral intermediate nucleus (VIM) is effective in alleviating medication-resistant tremor in patients with essential tremor (ET) and Parkinson's disease (PD). MR-guided focused ultrasound (MRgFUS) is an innovative technology that enables noninvasive thalamotomy via thermal ablation. METHODS Patients with severe medication-resistant tremor underwent unilateral VIM thalamotomy using MRgFUS. Effects on tremor were evaluated using the Clinical Rating Scale for Tremor (CRST) in patients with ET and by the motor part of the Unified Parkinson's Disease Rating Scale (UPDRS) in patients with PD and ET-PD (defined as patients with ET who developed PD many years later). Quality of life in ET was measured by the Quality of Life in Essential Tremor (QUEST) questionnaire and in PD by the PD Questionnaire (PDQ-39). RESULTS Thirty patients underwent MRgFUS, including 18 with ET, 9 with PD, and 3 with ET-PD. The mean age of the study population was 68.9 ± 8.3 years (range 46-87 years) with a mean disease duration of 12.1 ± 8.9 years (range 2-30 years). MRgFUS created a lesion at the planned target in all patients, resulting in cessation of tremor in the treated hand immediately following treatment. At 1 month posttreatment, the mean CRST score of the patients with ET decreased from 40.7 ± 11.6 to 9.3 ± 7.1 (p < 0.001) and was 8.2 ± 5.0 six months after treatment (p < 0.001, compared with baseline). Average QUEST scores decreased from 44.8 ± 12.9 to 13.1 ± 13.2 (p < 0.001) and was 12.3 ± 7.2 six months after treatment (p < 0.001). In patients with PD, the mean score of the motor part of the UPDRS decreased from 24.9 ± 8.0 to 16.4 ± 11.1 (p = 0.042) at 1 month and was 13.4 ± 9.2 six months after treatment (p = 0.009, compared with baseline). The mean PDQ-39 score decreased from 38.6 ± 16.8 to 26.1 ± 7.2 (p = 0.036) and was 20.6 ± 8.8 six months after treatment (p = 0.008). During follow-up of 6-24 months (mean 11.5 ± 7.2 months, median 12.0 months), tremor reappeared in 6 of the patients (2 with ET, 2 with PD, and 2 with ET-PD), to a lesser degree than before the procedure in 5. Adverse events that transiently occurred during sonication included headache (n = 11), short-lasting vertigo (n = 14) and dizziness (n = 4), nausea (n = 3), burning scalp sensation (n = 3), vomiting (n = 2) and lip paresthesia (n = 2). Adverse events that lasted after the procedure included gait ataxia (n = 5), unsteady feeling (n = 4), taste disturbances (n = 4), asthenia (n = 4), and hand ataxia (n = 3). No adverse event lasted beyond 3 months. Patients underwent on average 21.0 ± 6.9 sonications (range 14-45 sonications) with an average maximal sonication time of 16.0 ± 3.0 seconds (range 13-24 seconds). The mean maximal energy reached was 12,500 ± 4274 J (range 5850-23,040 J) with a mean maximal temperature of 56.5° ± 2.2°C (range 55°-60°C). CONCLUSIONS MRgFUS VIM thalamotomy to relieve medication-resistant tremor was safe and effective in patients with ET, PD, and ET-PD. Current results emphasize the superior adverse event...
Background. Thalamotomy is effective in alleviating tremor in Parkinson's disease (PD). Methods. Seven PD patients, mean age 59.4 ± 9.8 years (range, 46–74) with a mean disease duration of 5.4 ± 2.8 years (range, 2–10) suffering from severe refractory tremor, underwent ventral intermediate nucleus thalamotomy using MRI guided focused ultrasound (MRgFUS), an innovative technology that enables noninvasive surgery. Results. Tremor stopped in the contralateral upper extremity in all patients immediately following treatment. Total UPDRS decreased from 37.4 ± 12.2 to 18.8 ± 11.1 (p = 0.007) and PDQ-39 decreased from 42.3 ± 16.4 to 21.6 ± 10.8 (p = 0.008) following MRgFUS. These effects were sustained (mean follow-up 7.3 months). Adverse events during MRgFUS included headache (n = 3), dizziness (n = 2), vertigo (n = 4), and lip paresthesia (n = 1) and following MRgFUS were hypogeusia (n = 1), unsteady feeling when walking (n = 1, resolved), and disturbance when walking tandem (n = 1, resolved). Conclusions. Thalamotomy using MRgFUS is safe and effective in PD patients. Large randomized studies are needed to assess prolonged efficacy and safety.
The identification of a second mutation in SNAP29 in the present study definitely establishes a causal relationship between defective function of SNAP29 and the pleiotropic manifestations of CEDNIK syndrome. Our present and previous data position SNAP29 as an essential component of the epidermal differentiation machinery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.