A substantial number of incomplete KD cases were diagnosed based on the laboratory and echocardiographic criteria only. This was particularly the case in relation to infants younger than 1 year-an age group known to have an increased risk of developing coronary aneurysms. In addition, we found a high rate of underreporting to national Pediatric Surveillance Units. We suggest that improved surveillance and development of better diagnostic tests remain a high priority.
Summary. Purpose: To compare the performance of virtual and conventional colonoscopy for the detection of colorectal polyps using a multislice spiral CT scanner (MSCT). Materials and Methods: 48 patients (20 women, 28 men, mean age 61.5 years) with clinical indication for conventional colonoscopy were prospectively studied using a MSCT (Somatom Volume Zoom, Siemens, Forchheim). Examination was performed after standard oral preparation for colonoscopy and colonic distension with room air and i. v. butylscopolamin. Images were obtained in prone and supine position using a detector configuration of 4 1 mm, a table feed of 5 mm/rotation at 140 mAs and 120 kV. Slice thickness and reconstruction increment were 3 and 1.5 mm, respectively. CT data were assessed by two blinded radiologists on a Vitrea workstation (Vital Images, USA) using a software with multiplanar and volume-rendering capabilities. Results: 33 patients had normal findings on conventional colonoscopy. In 15 patients a total of 30 polyps and one carcinoma with stenosis were identified. MSCT-colonography identified the carcinoma and 23 polyps (77 %). 3 of 3 polyps were 10 mm or more (100 %), 6 of 7 were 5.1 to 9.9 mm (86 %) and 14 of 20 were 5 mm or smaller (70 %). There were 13 false positive findings for polyps (10 lesions < 6 mm in 5 patients) and no false positive finding of carcinoma. Conclusions: MSCT colonography allows accurate detection of polyps larger than 10 mm. Compared to published results of single-slice CT, multislice CT colonography increases the rate of detection of small colorectal polyps in particular. However, false positive results still remain a problem. Schlüsselwörter: Polypen ± Computertopographie ± Kolographie ± Mehrschicht-CT
These mid-term results after implantation of the No-React® Injectable BioPulmonic™ valve are disappointing. Graft failure was mainly due to neointimal formation and valve malposition.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.