Purpose To report the rate of technical complications and prosthesis survival in a cohort of edentulous patients treated with implant‐supported fixed complete dental prostheses (IFCDPs) after a mean observation period of at least 1 year. Materials and Methods The single‐visit examination included clinical and radiographic assessment, occlusal analysis, photographs and questionnaire assessing patient satisfaction in a cohort of 52 patients rehabilitated with 71 IFCDPs (supported by 457 implants). The IFCDPs were assessed for technical complications, number of implants and cantilever extension, retention type and prosthetic material type. Comparison was made between ceramic IFCDPs (Group 1) and metal‐resin IFCDPs (Group 2). Kaplan‐Meier survival curve analysis was carried out for assessment of prosthesis survival and was done for both Groups 1 and 2 separately. The Cox proportional hazard model was used for survival analysis, adjusting for a number of potential confounders, to evaluate the association between prosthesis survival and several risk factors such as type of opposing occlusion, nightguard use, and presence of bruxism. Responses to patient satisfaction questions were compared with Fisher's exact test. Results Out of 71 edentulous arches (52 patients) restored with IFCDPs, 6 IFCDPs had failed, yielding a cumulative prosthesis survival rate of 91.6 % after a mean observation period of 5.2 years (range: 1‐12 years) after definitive prosthesis insertion. Three IFCDPs were lost due to implant failures after 5.8 to 11 years of functional loading. Additionally, 3 metal‐resin IFCDPs failed due to technical complications. Minor complications were the most frequent complications observed, namely wear of the prosthetic material (9.8% annual rate) being the most common, followed by decementation of cement‐retained IFCDPs (2.9%), and loss of the screw access filing material of the screw‐retained IFCDPs (2.7%). The most frequently observed major complication was fracture of the prosthetic material (1.9% annual rate), followed by fracture of occlusal screw (0.3%), and fracture of framework (0.3%). The annual rate of wear of prosthetic material was 7.3% for porcelain IFCDPs (n = 19/55) and 19.4% for metal‐resin IFCDPs (n = 13/16), yielding a statistically significant difference between the 2 groups (p = 0.01). Conclusions After a mean exposure time of 5.2 years, 91.6% prosthesis survival rates were achieved (65 out of 71 IFCDPs). The most frequent minor technical complication was wear of the prosthetic material with estimated 5‐year rate of 49.0%, while the most frequent major complication was fracture of the prosthetic material with estimated 5‐year dental unit‐based rate of 9.5%. The cumulative rates for “prosthesis free of minor complications” at 5‐ and 10‐years were 60.5% (95% CI: 47.2‐71.3%) and 8.9% (95% CI: 2.9‐18.0%), respectively. The cumulative rates for “prosthesis free of major technical complications” at 5‐ and 10‐years were 85.5% (95% CI: 73.0‐92.5%) and 30.1% (95% CI: 12.0‐50.6%), respectively. Pr...
Purpose:To report the rate of technical complications and prosthesis survival in a cohort of edentulous patients treated with implant-supported fixed complete dental prostheses (IFCDPs) after a mean observation period of at least 1 year. Materials and Methods: The single-visit examination included clinical and radiographic assessment, occlusal analysis, photographs and questionnaire assessing patient satisfaction in a cohort of 52 patients rehabilitated with 71 IFCDPs (supported by 457 implants). The IFCDPs were assessed for technical complications, number of implants and cantilever extension, retention type and prosthetic material type. Comparison was made between ceramic IFCDPs (Group 1) and metal-resin IFCDPs (Group 2). Kaplan-Meier survival curve analysis was carried out for assessment of prosthesis survival and was done for both Groups 1 and 2 separately. The Cox proportional hazard model was used for survival analysis, adjusting for a number of potential confounders, to evaluate the association between prosthesis survival and several risk factors such as type of opposing occlusion, nightguard use, and presence of bruxism. Responses to patient satisfaction questions were compared with Fisher's exact test. Results: Out of 71 edentulous arches (52 patients) restored with IFCDPs, 6 IFCDPs had failed, yielding a cumulative prosthesis survival rate of 91.6 % after a mean observation period of 5.2 years (range: 1-12 years) after definitive prosthesis insertion. Three IFCDPs were lost due to implant failures after 5.8 to 11 years of functional loading. Additionally, 3 metal-resin IFCDPs failed due to technical complications. Minor complications were the most frequent complications observed, namely wear of the prosthetic material (9.8% annual rate) being the most common, followed by decementation of cement-retained IFCDPs (2.9%), and loss of the screw access filing material of the screw-retained IFCDPs (2.7%). The most frequently observed major complication was fracture of the prosthetic material (1.9% annual rate), followed by fracture of occlusal screw (0.3%), and fracture of framework (0.3%). The annual rate of wear of prosthetic material was 7.3% for porcelain IFCDPs (n = 19/55) and 19.4% for metal-resin IFCDPs (n = 13/16), yielding a statistically significant difference between the 2 groups (p = 0.01). Conclusions: After a mean exposure time of 5.2 years, 91.6% prosthesis survival rates were achieved (65 out of 71 IFCDPs). The most frequent minor technical complication was wear of the prosthetic material with estimated 5-year rate of 49.0%, while the most frequent major complication was fracture of the prosthetic material with estimated 5-year dental unit-based rate of 9.5%. The cumulative rates for "prosthesis free of minor complications" at 5-and 10-years were 60.5% (95% CI: 47.2-71.3%) and 8.9% (95% CI: 2.9-18.0%), respectively. The cumulative rates for "prosthesis free of major technical complications" at 5-and 10-years were 85.5% (95% CI: 73.0-92.5%) and
Several authors still consider the mechanical problems of fracture and component loosening as the main causes of failure of implant-supported restorations. The purpose of this in vitro study was to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque measurements. Three external hex fixtures were used, and each received a transmucosal abutment (Cera One®), which was fixed to the implant with its respective screw: Group A- gold screw, Group B- titanium screw and Group C- surface-treated titanium screw (Ti-Tite®). Ten screws of each type were attached applying a 30.07±0.28 Ncm torque force and maintained in position for 5 minutes. After this, the preload values were measured using strain gauges and a measurement cell. Gold screws presented higher preload values (131.72±8.98 N), followed by surface-treated titanium screws (97.78±4.68 N) and titanium screws (37.03±5.69 N). ANOVA (p<0.05) and Tukey's test (p<0.05) were applied. Statistically significant differences were found among the groups for both preload and removal torque values. In conclusion, gold screws may be indicated to achieve superior longevity of the abutment-implant connection and, consequently, prosthetic restoration due to greater preload values yielded.
The 6-mm implants supporting single crowns performed well, but the mandible shows a higher risk of failure. The time and clinical C/I ratio are predictors for bone loss.
The MAD treatment resulted in the reduction of SB activity, SB signs and symptoms, sleep disorders, and occlusal force.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.