Several authors still consider the mechanical problems of fracture and component loosening as the main causes of failure of implant-supported restorations. The purpose of this in vitro study was to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque measurements. Three external hex fixtures were used, and each received a transmucosal abutment (Cera One®), which was fixed to the implant with its respective screw: Group A- gold screw, Group B- titanium screw and Group C- surface-treated titanium screw (Ti-Tite®). Ten screws of each type were attached applying a 30.07±0.28 Ncm torque force and maintained in position for 5 minutes. After this, the preload values were measured using strain gauges and a measurement cell. Gold screws presented higher preload values (131.72±8.98 N), followed by surface-treated titanium screws (97.78±4.68 N) and titanium screws (37.03±5.69 N). ANOVA (p<0.05) and Tukey's test (p<0.05) were applied. Statistically significant differences were found among the groups for both preload and removal torque values. In conclusion, gold screws may be indicated to achieve superior longevity of the abutment-implant connection and, consequently, prosthetic restoration due to greater preload values yielded.
The purposes of this study were to develop a device to measure bracket debonding force in vivo and to evaluate, in vitro, the bond strength obtained with the device and with tensile and shear bond strength (SBS) tests performed in a universal testing machine. The device was developed using polypropylene pliers (3M Unitek). The basic principle consisted of measuring the applied force to debond, using two strain gauges (Kyowa) bonded to the region of major deformation of the plier handles. The crowns of 75 bovine incisors were embedded in acrylic resin and orthodontic brackets were bonded to the facial surface with Transbond XT (3M Unitek). In group A (n = 25) debonding was carried out with the device, while tensile bond strength testing was performed in group B (n = 25) and SBS testing in group C (n = 25). A universal testing machine (EMIC-DL-2,000) was used for these last two groups. According to analysis of variance and Tukey's test (alpha = 0.05), the mean bond strength for group C (7.71 MPa) was statistically higher than for groups A (2.98 MPa) and B (2.69 MPa). Groups A and B were not statistically different. The device was shown to be feasible to obtain in vivo bond strength values for orthodontic brackets, and that the bond strength values were dependent on the method and direction of debonding.
Um fator importante que define a eficácia dos aparelhos ortodônticos fixos é o atrito existente entre as superfícies de fios e braquetes. Assim, este estudo teve como objetivo investigar o coeficiente de atrito estático entre fios de aço inoxidável e beta-titânio (TP Orthodontics) e braquetes de aço inoxidável (Dynalock® - Unitek), braquetes estéticos com slot de aço inoxidável (Clarity® - Unitek) e estéticos convencionais (Allure® - GAC). Para tanto, construiu-se um equipamento no Departamento de Engenharia Mecânica e Mecatrônica da PUCRS. Antes de serem iniciados os testes, foi quantificado o erro de método e constatou-se que não houve interferência significante (p>0,05) do fator operador nas medições. Então, pôde-se calcular o valor do coeficiente de atrito, obtido pela divisão da força de atrito pela carga normal. O método estatístico utilizado neste estudo foi Análise de Variância (ANOVA) e teste de Comparações Múltiplas (Tukey). Constatou-se que: 1) a combinação com menor coeficiente de atrito foi composta pelo fio de aço inoxidável e braquete Dynalock® e a que apresentou maior coeficiente foi a do braquete Allure® com o fio de beta-titânio; 2) o fio de beta-titânio apresentou coeficiente de atrito significativamente maior do que o fio de aço inoxidável; 3) o braquete Dynalock® não apresentou diferenças significativas em relação ao coeficiente de atrito do braquete Clarity® quando o fio utilizado foi de beta-titânio. No entanto, quando o fio testado foi de aço inoxidável, apresentou coeficiente de atrito significativamente menor. O braquete Clarity® apresentou coeficiente de atrito significativamente menor do que o braquete Allure®.
An instrumented bicycle pedal was built and calibrated. The pedal has good linearity and sensibility, comparable to other instruments in the literature. This study aimed to perform accurate calibration of a tri-axial pedal, including forces applied, deformations, nonlinearities, hysteresis and standard error for each axis. Calibration was based on Hull and Davis method, which is based on the application of known loads on the pedal in order to create a calibration matrix.
Este trabalho objetiva demonstrar a metodologia chamada de Engenharia Reversa (ER) que, através de pontos obtidos por um equipamento de tomografia computadorizada, possibilita a criação de modelos digitais tridimensionais (3-D) de estruturas dentárias e de complexos implantares. As informações obtidas na digitalização do equipamento de tomografia são efetivadas através de um conjunto de pontos nos três eixos do sistema de coordenadas. A informação gerada na digitalização é um conjunto de pontos nos três eixos do sistema de coordenadas, e a união destes pontos é denominada de nuvens de pontos, no qual é gerado um arquivo texto, que será importado para uma ferramenta computacional, conhecida como Computer Aided Design (CAD). Depois de definida uma amostragem de pontos, é criado um modelo triangularizado sobre o qual serão produzidas curvas e superfícies e, então, trabalhado através de algoritmos de refinamento para obter o modelo virtual mais próximo do real. É, assim, gerado um arquivo. Uma vez gerado o modelo virtual, é possível fazer simulações e análises físicas. Algumas vantagens destas análises virtuais são: economia de tempo para a obtenção dos resultados, dispensa da utilização de laboratórios, redução de material, ou utilização de dentes físicos. O modelo gerado mostrou erros dimensionais da ordem de (0,8 ± 0,1) mm. Entretanto, a geometria é muito rica em detalhes encontrados no sistema real, como por exemplo, a estrutura dentária de um molar é apresentada com suas três diferentes composições: esmalte, dentina/cemento e polpa.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.