In the exercising human, maximal oxygen uptake (VO2max) is limited by the ability of the cardiorespiratory system to deliver oxygen to the exercising muscles. This is shown by three major lines of evidence: 1) when oxygen delivery is altered (by blood doping, hypoxia, or beta-blockade), VO2max changes accordingly; 2) the increase in VO2max with training results primarily from an increase in maximal cardiac output (not an increase in the a-v O2 difference); and 3) when a small muscle mass is overperfused during exercise, it has an extremely high capacity for consuming oxygen. Thus, O2 delivery, not skeletal muscle O2 extraction, is viewed as the primary limiting factor for VO2max in exercising humans. Metabolic adaptations in skeletal muscle are, however, critical for improving submaximal endurance performance. Endurance training causes an increase in mitochondrial enzyme activities, which improves performance by enhancing fat oxidation and decreasing lactic acid accumulation at a given VO2. VO2max is an important variable that sets the upper limit for endurance performance (an athlete cannot operate above 100% VO2max, for extended periods). Running economy and fractional utilization of VO2max also affect endurance performance. The speed at lactate threshold (LT) integrates all three of these variables and is the best physiological predictor of distance running performance.
The purpose of this investigation was to assess the accuracy of the COSMED K4 b2 portable metabolic measurement system against the criterion Douglas bag (DB) method. During cycle ergometry on consecutive days, oxygen consumption (VO2), carbon dioxide production (VCO2), minute ventilation (VE), and respiratory exchange ratio (R) were measured at rest and during power outputs of 50, 100, 150, 200, and 250W. No significant differences (P > 0.05) were observed in VO2 between the K4 b2 and DB at rest and at 250W. Though the K4 b2 values were significantly higher (P<0.05) than DB values at 50, 100, 150, and 200 W, the magnitude of these differences was small (0.088, 0.092, 0.096, and 0.088 L x min(-1), respectively). VCO2 and VE values from the K4 b2 were significantly lower than the DB at 200 and 250 W, while no significant differences were observed from rest through 150W. The slight overestimation of VO2 (50-200 W) combined with the underestimation of VCO2 (200 and 250W) by the K4 b2 resulted in significantly lower R values at every stage. These findings suggest the COSMED K4 b2 portable metabolic measurement system is acceptable for measuring oxygen uptake over a fairly wide range of exercise intensities.
In conclusion, a 24-wk walking program meeting the ACSM-CDC physical activity recommendation is effective in lowering systolic BP in postmenopausal women with borderline to stage 1 hypertension.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.