The aim of this study was to evaluate the association of COVID-19 factors and psychological factors with psychological distress among dental staff during the COVID-19 pandemic outbreak. A cross-sectional survey was conducted among 338 Israeli dentists and dental hygienists, who provided their demographic data; answered questions about COVID-19-related factors; and were assessed by subjective overload, self-efficacy, and psychological distress scales. Data were analyzed using a multivariate logistic regression. Results revealed that elevated psychological distress was found among those who have background illness, fear of contracting COVID-19 from patient, and a higher subjective overload. Lower psychological distress was associated with being in a committed relationship and having higher scores for self-efficacy. Given these results, gathered during times of an infectious disease outbreak, exploring psychological distress among dental staff is warranted as the effects may be long-term.
PurposeThe aim of this study was to compare the trueness and precision of four intraoral scanners used in oral implantology.MethodsTwo stone models were prepared, representing a partially and a totally edentulous maxilla, with three and six implant analogues, respectively, and polyether-ether-ketone (PEEK) cylinders screwed on. The models were digitized with an industrial scanner (IScan D104I®) used as a reference, and with four intraoral scanners (Trios®; CS 3500®; Zfx Intrascan®; Planscan®). Five scans were taken for each model, using each different intraoral scanner. All datasets were loaded into reverse-engineering software (Geomagics 2012®), where intraoral scans were superimposed on the reference model, to evaluate general trueness, and superimposed on each other within groups, to evaluate general precision. General trueness and precision of any scanner were compared by model type, through an ANOVA model including scanner, model and their interaction. Finally, the distance and angles between simulated implants were measured in each group, and compared to those of the reference model, to evaluate local trueness.ResultsIn the partially edentulous maxilla, CS 3500® had the best general trueness (47.8 μm) and precision (40.8 μm), followed by Trios® (trueness 71.2 μm, precision 51.0 μm), Zfx Intrascan® (trueness 117.0 μm, precision 126.2 μm), and Planscan® (trueness 233.4 μm, precision 219.8 μm). With regard to general trueness, Trios® was significantly better than Planscan®, CS 3500® was significantly better than Zfx Intrascan® and Planscan®, and Zfx Intrascan® was significantly better than Planscan®; with regard to general precision, Trios® was significantly better than Zfx Intrascan® and Planscan®, CS 3500® was significantly better than Zfx Intrascan® and Planscan®, and Zfx Intrascan® was significantly better than Planscan®. In the totally edentulous maxilla, CS 3500® had the best performance in terms of general trueness (63.2 μm) and precision (55.2 μm), followed by Trios® (trueness 71.6 μm, precision 67.0 μm), Zfx Intrascan® (trueness 103.0 μm, precision 112.4 μm), and Planscan® (trueness 253.4 μm, precision 204.2 μm). With regard to general trueness, Trios® was significantly better than Planscan®, CS 3500® was significantly better than Zfx Intrascan® and Planscan®, and Zfx Intrascan® was significantly better than Planscan®; with regard to general precision, Trios® was significantly better than Zfx Intrascan® and Planscan®, CS 3500® was significantly better than Zfx Intrascan® and Planscan®, and Zfx Intrascan® was significantly better than Planscan®. Local trueness values confirmed these results.ConclusionsAlthough no differences in trueness and precision were found between partially and totally edentulous models, statistically significant differences were found between the different scanners. Further studies are required to confirm these results.
BackgroundNowadays implant placement protocols are widespread among clinicians all over the world. However, available literature, only partially analyses what can be potential benefits for the clinicians and patients, often focusing just on specific aspects, such as accuracy. The purpose of this review is to compare computer guided implant placement with conventional treatment protocols.MethodsA search strategy according to the P-I-C-O format was developed and executed using an electronic MEDLINE plus manual search from 2000 up to December 2016. This review included only randomized controlled trials (RCTs) focusing on subjects treated with digital workflow for oral implant placement compared to conventional procedures. Data were extracted from eligible papers and analysed. All kinds of outcomes were considered, even patient-related and economical outcomes.ResultsThe search strategy revealed 16 articles; additional manual searches selected further 21 publications. Afterwards the evaluation of articles, only two studies could be selected for subsequent data extraction. The two identified RCTs analysed primary outcomes as prosthesis failure, implant failure, biological or prosthetic complications, and secondary outcomes as periimplant marginal bone loss. One RCT evaluated also the duration of treatment, post-surgical progress, additional treatment costs and patient satisfaction. The other RCT focused instead on evaluating eventual improvement of patient’s quality of life. In both selected studies, were not observed by the authors statistically significant differences between clinical cases treated with digital protocols and those treated with conventional ones. In one RCT, however post-surgical progress evaluation showed more patients’ self-reported pain and swelling in conventional group.ConclusionsWithin the limitation of this review, based on only two RCTs, the only evidence was that implant survival rate and effectiveness are similar for conventional and digital implant placement procedures. This is also confirmed by many other studies with however minor scientific evidence levels. Reduction of post-operative pain, surgical time and overall costs are discussed. Authors believe that scientific research should focus more in identifying which clinical situations can get greatest benefits from implant guided surgery. This should be done with research protocols such as RCT that assess comprehensively the advantages and disadvantages of fully digital surgical protocols.
BackgroundPolymer infiltrated ceramics and nano-ceramic resins are the new restorative materials which have been developed in order to enhance the adverse properties of glass-matrix ceramics and resin composites. The aim of the present in vitro study was to evaluate the characteristics of various CAD/CAM materials through mechanical, microstructural, and SEM analysis.MethodsFive test groups (n = 22) were formed by using the indicated CAD/CAM blocks: VITA Enamic (VITA Zahnfabrik), Lava Ultimate (3 M ESPE), IPS e.max CAD (Ivoclar Vivadent), IPS Empress CAD (Ivoclar Vivadent), and VITA Mark II (VITA Zahnfabrik). Two specimens from each test group were used for XRD and EDS analysis. Remaining samples were divided into two subgroups (n = 10). One subgroup specimens were thermocycled (5 °C to 55 °C, 30s, 10,000 cycles) whereas the other were not. All of the specimens were evaluated in terms of flexural strength, Vickers hardness, and fracture toughness. Results were statistically analyzed using two-way ANOVA, one-way ANOVA, Tukey’s HSD, and Student’s t tests (α = .05). Fractured specimens were evaluated using SEM.ResultsThe highest Vickers microhardness value was found for VITA Mark II (p < .001), however flexural strength and fracture toughness results were lowest conversely (p < .05). IPS e.max CAD was found to have the highest flexural strength (p < .001). Fracture toughness of IPS e.max CAD was also higher than other tested block materials (p < .001). Lava Ultimate and VITA Enamic’s mechanical properties were affected negatively from thermocycling (p < .05). Microhardness, flexural strength, and fracture toughness values of Lava Ultimate and VITA Enamic were found to be similar to VITA Mark II and IPS Empress CAD groups.ConclusionsIt should be realised that simulated aging process seem to affect ceramic-polymer composite materials more significantly than glass ceramics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.