The AeroForm chest wall tissue expander (TE) is a silicon shell containing a metallic CO 2 reservoir, placed surgically after mastectomy. The patient uses a remote control to release compressed CO 2 from the reservoir to inflate the expander. AeroForm poses challenges in a radiation therapy setting: The high density of the metallic reservoir causes imaging artifacts on the planning CT, which encumber structure definition and cause misrepresentation of density information, in turn affecting dose calculation. Additionally, convolution‐based dose calculation algorithms may not be well‐suited to calculate dose in and around high‐density materials. In this study, a model of the AeroForm TE was created in Eclipse treatment planning system (TPS). The TPS model was validated by comparing measured to calculated transmission through the AeroForm. Transmission was measured with various geometries using radiochromic film. Dose was calculated with both Varian’s Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB) algorithms. AAA and AXB were compared using dose profile and gamma analyses. While both algorithms modeled direct transmission well, AXB better modeled lateral scatter from the AeroForm TE. Clinical significance was evaluated using clinical data from four patients with AeroForm TEs. The AeroForm TPS model was applied, and RT plans were optimized using AAA, then re‐calculated with AXB. Structures of clinical significance were defined and dose volume histogram analysis was performed. Compared to AXB, AAA overestimates dose in the AeroForm device. Changes in clinically significant regions were patient‐ and plan‐specific. This study proposes a clinical procedure for modeling the AeroForm in a commercial TPS, and discusses the limitations of dose calculation in and around the device. An understanding of dose calculation accuracy in the vicinity of the AeroForm is critical for assessing individual plan quality, appropriateness of different planning techniques and dose calculation algorithms, and even the decision to use the AeroForm in a postmastectomy radiation therapy setting.
Purpose: To validate benefit of using a breast board (BB) by analyzing the geometry and dosimetry changes of the regions of interest (ROIs) between CT scans with and without BB. Methods: Seven patients, two chest walls (CW) and five breasts, use BB at CT simulation and no BB at diagnostic CT were included. By using deformable image registration software (Velocity AI), diagnostic CT and planning CT were rigidly co‐registered according to the thoracic cage at the target. The heart and the target were then deformedly matched and the contours of the planned ROIs were transferred to the diagnostic CT. Which were brought back to the planning CT data set though the initial rigid co‐registration in order to keep the deformed ROIs redefined in the diagnostic CT. Anatomic shifts and volume changes of a ROI beyond the rigid translation were recorded and dosimetry changes to ROIs were compared with recalculated DVHs. Results: Patient setup without the BB had small but systematic heart shifts superiorly by ∼5 mm. Torso rotations in two cases moved the heart in opposite directions by ∼10 mm. The breast target volume, shape, and locations were significantly changed with arm extension over the head but not in cases with the arm extended laterally. Breast setup without BB could increase the mean dose to the heart and the maximal dose to the anterior ventricle wall by 1.1 and 6.7 Gy, respectively. Conclusion: A method for evaluation of breast setup technique is introduced and applied for patients. Results of systematic heart displacement without using the BB and the potential increase of heart doses encourage us to further investigate the current trend of not using a BB for easy setup and CT scans. Using a BB would likely increase patient sag during prolonged IMRT and real‐time patient position monitoring is clinically desired.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.