Background-Precise knowledge of left atrial appendage (LAA) orifice size is crucial for correct sizing of LAA closure devices. The aim of the present study was to determine the performance of real-time 3D transesophageal echocardiography (RT3DTEE) for LAA orifice size assessment, compared with 2D transesophageal echocardiography (2DTEE), and to investigate the impact of atrial fibrillation (AF) on LAA orifice size.
BACKGROUND: Percutaneous mitral valve repair (MVR) using the MitraClip system has become a valid alternative for patients with severe mitral regurgitation (MR) and high operative risk. OBJECTIVE: To identify clinical and periprocedural factors that may have an impact on clinical outcome. DESIGN: Multi-centre longitudinal cohort study. SETTING: Tertiary referral centres. PATIENTS: Here we report on the first 100 consecutive patients treated with percutaneous MVR in Switzerland between March 2009 and April 2011. All of them had moderate-severe (3+) or severe (4+) MR, and 62% had functional MR. 82% of the patients were in New York Heart Association (NYHA) class III/IV, mean left ventricular ejection fraction was 48% and the median European System for Cardiac Operative Risk Evaluation was 16.9%. INTERVENTIONS: MitraClip implantation performed under echocardiographic and fluoroscopic guidance in general anaesthesia. MAIN OUTCOME MEASURES: Clinical, echocardiographic and procedural data were prospectively collected. RESULTS: Acute procedural success (APS, defined as successful clip implantation with residual MR grade 2+) was achieved in 85% of patients. Overall survival at 6 and 12 months was 89.9% (95% CI 81.8 to 94.6) and 84.6% (95% CI 74.7 to 91.0), respectively. Univariate Cox regression analysis identified APS (p=0.0069) and discharge MR grade (p=0.03) as significant predictors of survival. CONCLUSIONS: In our consecutive cohort of patients, APS was achieved in 85%. APS and residual discharge MR grade are important predictors of mid-term survival after percutaneous MVR.
ObjectiveAnalyse 2-year outcomes after MitraClip therapy and identify predictors of outcome.MethodsConsecutive patients (n=74) undergoing MitraClip therapy were included in the MitraSWISS registry and followed prospectively.ResultsA reduction of mitral regurgitation (MR) to ≤ mild was achieved in 32 (43%) patients and to moderate in 31 (42%) patients; 16/63 (25%) patients with initially successful treatment developed recurrent moderate to severe or severe MR during the first year and only 1 patient did so during the second year. At 2 years, moderate or less MR was more frequently present in patients with a transmitral mean gradient <3 mm Hg at baseline (73% vs 23%, p < 0.01) and in patients with a left atrial volume index (LAVI) <50 mL/m2 at baseline (86% vs 52%, p=0.03). More than mild MR post MitraClip, N-terminal probrain natriuretic peptide ≥5000 ng/L at baseline, chronic obstructive pulmonary disease (COPD) and chronic kidney disease (CKD) were associated with reduced survival.ConclusionsA mean transmitral gradient <3 mm Hg at baseline, an LAVI <50 mL/m2, the absence of COPD and CKD, and reduction of MR to less than moderate were associated with favourable outcome. Given a suitable anatomy, such patients may be excellent candidates for MitraClip therapy. Between 1 and 2 years follow-up, clinical and echocardiographic outcomes were stable, suggesting favourable, long-term durability of the device.
Guidance of catheter-based procedures is performed using fluoroscopy and 2-dimensional transesophageal echocardiography (TEE). Both of these imaging modalities have significant limitations. Because of its 3-dimensional (3D) nature, 3D TEE allows visualizing the entire scenario in which catheter-based procedures take place (including long segments of catheters, tips, and the devices) in a single 3D view. Despite these undeniable advantages, 3D TEE has not yet gained wide acceptance among most interventional cardiologists and echocardiographists. One reason for this reluctance is probably the absence of standardized approaches for obtaining 3D perspectives that provide the most comprehensive information for any single step of any specific procedure. Therefore, the purpose of this review is to describe what we believe to be the most useful 3D perspectives in the following catheter-based percutaneous interventions: transseptal puncture; patent foramen ovale/atrial septal defect closure; left atrial appendage occlusion; mitral valve repair; and closure of paravalvular leaks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.