An open-ended coaxial sensor for the determination of complex permittivity and moisture content of oil palm fruits is presented in this paper. The measurement system consisting of the sensor and a PC-controlled vector network analyzer have been tested successfully on a range of oil palm fruits of various degrees of ripeness. The initial values of the complex permittivity were estimated using the admittance model of the sensor. The amount of moisture content was found by matching the values of permittivity from the quasistatic model with the permittivity of a dielectric mixture model using the moisture content values obtained from the standard oven drying method.
This paper presents the modeling of breast tumor imaging process using wire mesh collimator gamma camera. Previous studies showed that the wire mesh collimator has a potential to improve the sensitivity of the tumor detection. In this paper, we extend our research significantly, to find an optimal configuration of the wire mesh collimator specifically for semi-compressed breast tumor detection, by looking into four major factors: weight, sensitivity, spatial resolution and tumor contrast. The numbers of layers in the wire mesh collimator is varied to optimize the collimator design. The statistical variations of the results are studied by simulating multiple realizations for each experiment using different starting random numbers. All the simulation environments are modeled using Monte Carlo N-Particle Code (MCNP). The quality of the detection is measured directly by comparing the sensitivity, spatial resolution and tumor contrast of the images produced by the wire mesh collimator and benchmarked that with a standard multihole collimator. The proposed optimal configuration of the wire mesh collimator is optimized by selecting the number of layers in wire mesh collimator, where the tumor contrast shows a relatively comparable value to the multihole collimator, when it is tested with uniformly semi-compressed breast phantom. The wire mesh collimator showed higher number of sensitivity because of its loose arrangement while the spatial resolution of wire mesh collimator does not shows much different compared to the multihole collimator. With a relatively good tumor contrast and spatial resolution, and increased in sensitivity, a new proposed wire mesh collimator gives a significant improvement in the wire mesh collimator design for breast cancer imaging process. The proposed collimator configuration is reduced to 44.09% from the total multihole collimator weight.
An analytical model for a double Si/Si 1−x Ge x QW-PMOS is developed for the determination of the threshold voltages and an estimate of the hole densities in each conducting QW-channel including the silicon surface channel. Detailed analysis of the uncoupled retrograded double Si/Si 1−x Ge x QW-PMOS is carried out with varying structural and physical parameters. The model adequately describes and predicts the best design choice of the double QW structure for optimum device performance. The procedure for the evaluation of the optimum structure is not just limited to QW-PMOSs in bulk silicon technology but can be also successfully applied for realizing QW-NMOS structures on relaxed Si 1−x Ge x buffer layers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.