CAD is frequent among patients with severe AS undergoing TAVI. Among carefully selected patients, revascularisation by means of PCI can be safely performed in addition to TAVI either as a staged or a concomitant intervention.
Transcatheter LAA occlusion for stroke prophylaxis in patients with atrial fibrillation can be performed with similarly high success rates with first and second generations of Amplatzer occluders. According to this early experience, the Amulet has failed to improve results of LAA occlusion. The risk for major procedural adverse events is acceptable but has to be taken into account when selecting patients for LAA occlusion, a preventive procedure.
BackgroundTranscatheter aortic valve implantation (TAVI) is a well-established
procedure; however, atrioventricular block requiring permanent pacemaker
implantation (PPI) is a common complication.ObjectivesTo determine the incidence, predictors and clinical outcomes of PPI after
TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF)
after TAVI.MethodsThe Brazilian Multicenter TAVI Registry included 819 patients submitted to
TAVI due to severe aortic stenosis from 22 centers from January/2008 to
January/2015. After exclusions, the predictors of PPI were assessed in 670
patients by use of multivariate regression. Analysis of the ROC curve was
used to measure the ability of the predictors; p < 0.05 was the
significance level adopted.ResultsWithin 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients
were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex
(59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients
submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p
< 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p =
0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of
multivariate analysis, the previous presence of right bundle-branch block
(RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of
CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤
0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2;
p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%,
when none of those predictors was present, to 63%, in the presence of all of
them. The model showed good ability to predict the need for PPI: 0.69
(95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms
during the 1-year follow-up showed worse LVEF course in patients submitted
to PPI (p = 0.01).ConclusionBRD prévio, gradiente aórtico médio > 50 mmHg e
CoreValve® são preditores independentes de implante de MPD
pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de
TAVI, o que prolongou a internação hospitalar, mas não
afetou a mortalidade. O implante de MPD afetou negativamente a FEVE
pós-TAVI.
Total percutaneous techniques or surgical cutdown and closure may provide similar safety and effectiveness during the first year of follow-up in patients undergoing transfemoral TAVI.
SummaryBackground: Central anthropometric indexes are better than the body mass index to discriminate elevated coronary risk. However, the Body Mass Index (BMI) is still the most frequently studied anthropometric index on outcomes of patients undergoing percutaneous coronary angioplasty (PCI).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.