Arachnoid cysts are space-occupying lesions filled with CSF-like content and surrounded by a membrane resembling arachnoid matter. They are regarded as a development abnormality of the arachnoid, originating from a splitting or duplication of this membrane. However, precise etiology and natural history remain controversial. Different hypotheses have been developed including agenesis of brain structures, arachnoiditis, active fluid secretion, and pulsatile pump. We present a review of the literature concerning these items and report one case of a suprasellar arachnoid cyst in which a slit-valve mechanism was observed by means of cine-mode MRI preoperatively and confirmed during the endoscopic intervention.
Objectives-The fibreoptic device is a type of intracranial pressure monitor which seems to oVer certain advantages over conventional monitoring systems. This study was undertaken to analyse the accuracy, drift characteristics, and complications of the Camino® fibreoptic device. Methods-One hundred and eight Camino® intracranial pressure (ICP) devices, in their three modalities, were implanted during 1997. The most frequent indication for monitoring was severe head injury due to road traYc accidents. Results-Sixty eight probe tips were cultured; 13.2% of the cases had a positive culture without clinical signs of infection, and 2.9% had a positive culture with clinical signs of ventriculitis. The most common isolated pathogen was Staphylococcus epidermidis. All patients were under cephalosporin prophylaxis during monitoring. Haemorrhage rate in patients without coagulation disorders was 2.1% and 15.3% in patients with coagulation abnormalities. Drift characteristics were studied in 56 cases; there was no drifting from the values expected according to the manufacturer's specifications in 34 probes. There was no relation between direction of the drift and duration of placement, nor between drift and time. Conclusions-Although the complication and drift rates were similar to those reported elsewhere, there was no correlation between the direction of the drift and long term monitoring despite the fact that some published papers refer to overestimation of values with time with this type of device. (J Neurol Neurosurg Psychiatry 2000;69:82-86)
The results from published series concerning surgical complications after craniotomies for brain tumours are not comparable because of the lack of homogeneity between them. The knowledge of the complications rate in each particular neurosurgical department turns out essentially to provide the patient with tailored information about risks before surgery.
The management of pineal tumours remains controversial. During 1994 we treated four consecutive adults (16-44 yrs) harbouring a pineal tumour with a neuroendoscopic procedure. All of them presented with hydrocephalus. Pre-operative workup included cranial computerized tomography (CT), craniospinal magnetic resonance imaging (MRI) and serum levels of biological tumour markers. The endoscopic procedure consisted of a third ventriculostomy followed by biopsy with a flexible, steerable neuroendoscope. Histological diagnosis was achieved in three patients who no longer required a shunt device. Recorded complications were: bleeding during ventriculostomy that prevented us from obtaining a good sample for biopsy, short-term memory loss that cleared over a two-week period, and transient increase of pre-operative hemiparesis. Complications and morbidity are emphasized so as to be avoided with further technical experience. Neuroendoscopy affords a minimally invasive way of reaching three objectives by one-step surgery in the management of pineal region lesions: 1) CSF sample for analysis of tumour markers. 2) Treatment of hydrocephalus by third ventriculostomy. 3) Several biopsy specimens can be obtained identifying tumours which will require further open surgery or adjuvant radiation and/or chemotherapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.