Background: Intestinal exposure to gliadin leads to zonulin upregulation and consequent disassembly of intercellular tight junctions and increased intestinal permeability. We aimed to study response to gliadin exposure, in terms of barrier function and cytokine secretion, using intestinal biopsies obtained from four groups: celiac patients with active disease (ACD), celiac patients in remission (RCD), non-celiac patients with gluten sensitivity (GS) and non-celiac controls (NC). Methods: Ex-vivo human duodenal biopsies were mounted in microsnapwells and luminally incubated with either gliadin or media alone. Changes in transepithelial electrical resistance were monitored over 120 min. Media was subsequently collected and cytokines quantified. Results: Intestinal explants from all groups (ACD (n = 6), RCD (n = 6), GS (n = 6), and NC (n = 5)) demonstrated a greater increase in permeability when exposed to gliadin vs. media alone. The increase in permeability in the ACD group was greater than in the RCD and NC groups. There was a greater increase in permeability in the GS group compared to the RCD group. There was no difference in permeability between the ACD and GS groups, between the RCD and NC groups, or between the NC and GS groups. IL-10 was significantly greater in the media of the NC group compared to the RCD and GS groups. Conclusions: Increased intestinal permeability after gliadin exposure occurs in all individuals. Following gliadin exposure, both patients with gluten sensitivity and those with active celiac disease demonstrate a greater increase in intestinal permeability than celiacs in disease remission. A higher concentration of IL-10 was measured in the media exposed to control explants compared to celiac disease in remission or gluten sensitivity.
BACKGROUND:
Over 6 million esophagogastroduodenoscopy (EGD) procedures are performed in the United States each year. Patients having anesthesia for advanced EGD procedures, such as interventional procedures, are at high risk for hypoxemia.
METHODS:
Our primary study aim was to evaluate whether high-flow nasal cannula (HFNC) oxygen reduces the incidence of hypoxemia during anesthesia for advanced EGD. Secondarily, we studied whether HFNC oxygen reduces hypercarbia or hypotension. After obtaining written informed consent, adults having anesthesia for advanced EGD, expected to last longer than 15 minutes, were randomly assigned to receive HFNC oxygen or standard nasal cannula (SNC) oxygen. The primary outcome was occurrence of one or more hypoxemia events during anesthesia, defined by arterial oxygen saturation <92% for at least 15 consecutive seconds. Secondary outcomes were occurrence of one or more hypercarbia or hypotension events. A hypercarbia event was defined by a transcutaneous CO2 measurement 20 mm Hg or more above baseline, and a hypotension event was defined by a mean arterial blood pressure measurement 25% or more below baseline.
RESULTS:
Two hundred seventy-one adult patients were enrolled and randomized, and 262 patients completed study procedures. Eight randomized patients did not complete study procedures due to changes in their anesthesia or endoscopy plan. One patient was excluded from analysis because their procedure was aborted after 1 minute. Patients who received HFNC oxygen (N = 132) had a significantly lower incidence of hypoxemia than those who received SNC oxygen (N = 130; 21.2% vs 33.1%; hazard ratio [HR] = 0.59 [95% confidence interval {CI}, 0.36–0.95]; P = .03). There was no difference in the incidence of hypercarbia or hypotension between the groups. The HR for hypercarbia with HFNC oxygen was 1.29 (95% CI, 0.89–1.88; P = .17), and the HR for hypotension was 1.25 (95% CI, 0.86–1.82; P = .25).
CONCLUSIONS:
HFNC oxygen reduces the incidence of hypoxemia during anesthesia for advanced EGD and may offer an opportunity to enhance patient safety during these procedures.
Overall, the detection rates in this study are lower than previously reported and not influenced by increasing experience. Detection rates are significantly higher when reading in SingleView 15 and QuadView 20 compared with reading in SingleView 25. Increasing viewing speed from QuadView 20 to QuadView 30 appears to have no significant effect on detection. Quality control measures to compare and improve lesion detection rates need further study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.