This article describes the design and evaluation of AutoSyP, a low-cost, low-power syringe pump intended to deliver intravenous (IV) infusions in low-resource hospitals. A constant-force spring within the device provides mechanical energy to depress the syringe plunger. As a result, the device can run on rechargeable battery power for 66 hours, a critical feature for low-resource settings where the power grid may be unreliable. The device is designed to be used with 5- to 60-mL syringes and can deliver fluids at flow rates ranging from 3 to 60 mL/hour. The cost of goods to build one AutoSyP device is approximately $500. AutoSyP was tested in a laboratory setting and in a pilot clinical study. Laboratory accuracy was within 4% of the programmed flow rate. The device was used to deliver fluid to 10 healthy adult volunteers and 30 infants requiring IV fluid therapy at Queen Elizabeth Central Hospital in Blantyre, Malawi. The device delivered fluid with an average mean flow rate error of −2.3% ± 1.9% for flow rates ranging from 3 to 60 mL/hour. AutoSyP has the potential to improve the accuracy and safety of IV fluid delivery in low-resource settings.
Abstract. We designed and evaluated the accuracy and usability of a device to regulate the volume of fluid dispensed during intravenous drip therapy. The mechanical system was developed in response to a pressing need articulated by clinicians in pediatric wards throughout sub-Saharan Africa, who require a tool to prevent overhydration in children receiving intravenous fluid in settings that lack burettes or electronic infusion pumps. The device is compatible with most intravenous bags and limits the volume dispensed to a preset amount that can be adjusted in 50 mL increments. Laboratory accuracy over a range of clinically-relevant flow rates, initial bag volumes, and target volumes was within 12.0 mL of the target volume. The ease of use is "excellent," with a mean system usability score of 84.4 out of 100. Use of the device limits the volume of fluid dispensed during intravenous therapy and could potentially reduce the morbidity and mortality associated with overhydration in children receiving intravenous therapy.
BackgroundMagnesium sulfate is an affordable and effective treatment for pre-eclampsia and eclampsia. In settings where infusion pumps are not available to regulate the flow rate of intravenous delivery, healthcare providers must administer magnesium sulfate (MgSO4) via time-consuming and painful, large-volume intramuscular injections. As an alternative to costly commercially available syringe pumps, we developed AutoSyp, an accurate, low-cost, and low-powered syringe pump designed to meet the needs and constraints these low-resource settings. This paper describes results of a pilot study to evaluate the feasibility of using AutoSyp to administer MgSO4 intravenously to women suffering from pre-eclampsia at a referral hospital in Blantyre, Malawi.MethodsAutoSyp was programmed to deliver MgSO4 following the Zuspan regimen to pregnant and post-partum women suffering from pre-eclampsia at Queen Elizabeth Central Hospital in Blatnyre, Malawi. Given the selection of either loading or maintenance dose on AutoSyp’s user interface, the flow rate was automatically programmed to dispense 60 mL/h or 5 mL/h of 20% MgSO4 solution, respectively. During each treatment, the dispensed volume was automatically calculated by the device based on the plunger position and stored on a computer for accuracy analysis of the mean flow rate and total volume delivered. The clinical results for both the loading and maintenance dose administrations were compared to the device’s accuracy during tests performed in the laboratory setting.ResultsTwenty-two women were enrolled in this study. In both the clinical and laboratory settings, the mean flow rate errors for the loading and maintenance dose infusions were under 2%. During 466 h of testing, the device sounded 129 occlusion alarms across 14 subjects. Of these, 71 alarms were false positives.ConclusionResults of this study support the use of AutoSyp as a less painful and accurate means of MgSO4 administration in clinical environments that lack infusion systems.There were a large number of false alarms in the current system which will be addressed in future designs. AutoSyp maintains the comfort of intravenous MgSO4 administration, but unlike commercially available syringe pumps, it is capable of operating with a variety of syringe brands and sizes and requires no additional consumables. AutoSyp’s appropriate design will benefit its implementation and sustained use in low-resource settings.Trial RegistrationTrial registered prospectively on November 18, 2014 with ClinicalTrials.gov (NCT02296931)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.