Patch-clamp recording has enabled single-cell electrical, morphological and genetic studies at unparalleled resolution. Yet it remains a laborious and low-throughput technique, making it largely impractical for large-scale measurements such as cell type and connectivity characterization of neurons in the brain. Specifically, the technique is critically limited by the ubiquitous practice of manually replacing patch-clamp pipettes after each recording. To circumvent this limitation, we developed a simple, fast, and automated method for cleaning glass pipette electrodes that enables their reuse within one minute. By immersing pipette tips into Alconox, a commercially-available detergent, followed by rinsing, we were able to reuse pipettes 10 times with no degradation in signal fidelity, in experimental preparations ranging from human embryonic kidney cells to neurons in culture, slices, and in vivo. Undetectable trace amounts of Alconox remaining in the pipette after cleaning did not affect ion channel pharmacology. We demonstrate the utility of pipette cleaning by developing the first robot to perform sequential patch-clamp recordings in cell culture and in vivo without a human operator.
Direct delivery of fluid to brain parenchyma is critical in both research and clinical settings. This is usually accomplished through acutely inserted cannulas. This technique, however, results in backflow and significant dispersion away from the infusion site, offering little spatial or temporal control in delivering fluid. We present an implantable, MRI-compatible, remotely controlled drug delivery system for minimally invasive interfacing with brain microstructures in freely moving animals. We show that infusions through acutely inserted needles target a region more than twofold larger than that of identical infusions through chronically implanted probes due to reflux and backflow. We characterize the dynamics of in vivo infusions using positron emission tomography techniques. Volumes as small as 167 nL of copper-64 and fludeoxyglucose labeled agents are quantified. We further demonstrate the importance of precise drug volume dosing to neural structures to elicit behavioral effects reliably. Selective modulation of the substantia nigra, a critical node in basal ganglia circuitry, via muscimol infusion induces behavioral changes in a volume-dependent manner, even when the total dose remains constant. Chronic device viability is confirmed up to 1-y implantation in rats. This technology could potentially enable precise investigation of neurological disease pathology in preclinical models, and more efficacious treatment in human patients.
Neurochemical dysregulation underlies many pathologies and can be monitored by measuring the composition of brain interstitial fluid (ISF). Existing in vivo tools for sampling ISF do not enable measuring large rare molecules, such as proteins and neuropeptides, and thus cannot generate a complete picture of the neurochemical connectome. Our micro-invasive platform, composed of a nanofluidic pump coupled to a membrane-free probe, enables sampling multiple neural biomarkers in parallel. This platform outperforms the state of the art in low-flow pumps by offering low volume control (single stroke volumes, <3 nl) and bidirectional fluid flow (<100 nl/min) with negligible dead volume (<30 nl) and has been validated in vitro, ex vivo, and in vivo in rodents. ISF samples (<1.5 μL) can be processed via liquid chromatography–tandem mass spectrometry. These label-free liquid biopsies of the brain could yield a deeper understanding of the onset, mechanism, and progression of diverse neural pathologies.
Enhanced understanding of neuropathologies has created a need for more advanced tools. Current neural implants result in extensive glial scarring and are not able to highly localize drug delivery due to their size. Smaller implants reduce surgical trauma and improve spatial resolution, but such a reduction requires improvements in device design to enable accurate and chronic implantation in subcortical structures. Flexible needle steering techniques offer improved control over implant placement, but often require complex closed‐loop control for accurate implantation. This study reports the development of steerable microinvasive neural implants (S‐MINIs) constructed from borosilicate capillaries (OD = 60 µm, ID = 20 µm) that do not require closed‐loop guidance or guide tubes. S‐MINIs reduce glial scarring 3.5‐fold compared to prior implants. Bevel steered needles are utilized for open‐loop targeting of deep‐brain structures. This study demonstrates a sinusoidal relationship between implant bevel angle and the trajectory radius of curvature both in vitro and ex vivo. This relationship allows for bevel‐tipped capillaries to be steered to a target with an average error of 0.23 mm ± 0.19 without closed‐loop control. Polished microcapillaries present a new microinvasive tool for chronic, predictable targeting of pathophysiological structures without the need for closed‐loop feedback and complex imaging.
Optical phase conjugation (OPC) is of interest for many applications. The generation of squeezed light, phase-conjugate mirrors, optical correlation, and turbulence correction would all benefit from improved OPC performance. Using Zeeman sublevels and cross-circularly polarized light in rubidium vapor, we demonstrate an OPC process that uses very low power (30 mW) but is still very fast (60 ns) and efficient (gain of 20). This process is generic enough to be applicable to almost any resonant medium.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.