Background—
Aortic valve stenosis (AS) induces compensatory alterations in left ventricular hemodynamics, leading to physiological and pathological alterations in coronary hemodynamics. Relief of AS by transcatheter aortic valve implantation (TAVI) decreases ventricular afterload and is expected to improve microvascular function immediately. We evaluated the effect of AS on coronary hemodynamics and the immediate effect of TAVI.
Methods and Results—
Intracoronary pressure and flow velocity were simultaneously assessed at rest and at maximal hyperemia in an unobstructed coronary artery in 27 patients with AS before and immediately after TAVI and in 28 patients without AS. Baseline flow velocity was higher and baseline microvascular resistance was lower in patients with AS as compared with controls, which remained unaltered post-TAVI. In patients with AS, hyperemic flow velocity was significantly lower as compared with controls (44.5±14.5 versus 54.3±18.6 cm/s;
P
=0.04). Hyperemic microvascular resistance (expressed in mm Hg·cm·s
−1
) was 2.10±0.69 in patients with AS as compared with 1.80±0.60 in controls (
P
=0.096). Coronary flow velocity reserve in patients with AS was lower, 1.9±0.5 versus 2.7±0.7 in controls (
P
<0.001). Improvement in coronary hemodynamics after TAVI was most pronounced in patients without post-TAVI aortic regurgitation. In these patients (n=20), hyperemic flow velocity increased significantly from 46.24±15.47 pre-TAVI to 56.56±17.44 cm/s post-TAVI (
P
=0.003). Hyperemic microvascular resistance decreased from 2.03±0.71 to 1.66±0.45 (
P
=0.050). Coronary flow velocity reserve increased significantly from 1.9±0.4 to 2.2±0.6 (
P
=0.009).
Conclusions—
The vasodilatory reserve capacity of the coronary circulation is reduced in AS. TAVI induces an immediate decrease in hyperemic microvascular resistance and a concomitant increase in hyperemic flow velocity, resulting in immediate improvement in coronary vasodilatory reserve.
Minimally invasive mitral valve repair is safe, with low perioperative morbidity, low rates of recurrent mitral regurgitation, and low rates of reoperation and death at late follow-up.
In patients aged <65 years, despite an increase in the rate of reoperation with stented bioprosthetic valves and an increase in major bleeding events with mechanical valves, there is no significant difference in mortality at late follow-up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.