The paper analyzes how the switching system of an electronic load influences the reactive power of the bus, and how they behave as active filters when connected in parallel. In laboratory, didactic electronic loads were used, both called Dimmer Flex, and the works divided into three cases. In the first case, the electronic load starts applying voltage, after half of each half-cycle, the current was interrupted and, according to the meters, reactive power was injected into the bus. In the second case, Dimmer Flex was used to break the start of the current at around half of the each half-cycle, and reactive power was absorbed from the bus. In the third case, the first device was positioned in parallel with the second, and the reactive power flow was almost completely compensated and the harmonic distortion value of the current decreased, proving its role as an active filter.
Agradeço à minha mãe, Mariene, pelo exemplo, força, apoio e carinho, sem ela nada disso seria possível. Ela sempre confiou no meu potencial e me ensinou que tudo é possível quando damos nosso melhor. À minha vó, Marilene, pelo apoio e carinho todos os dias.Aos meus amigos, Amanda, Rudíny e Matheus, por me ouvirem em cada momento de dificuldade e alegria e por todo amor, apoio, força e incentivo.Aos meus novos amigos de São Carlos, Jéssica, Gabriel, Geovane e João H., pelo companheirismo e incentivo.Ao José Paulo que me ajudou no desenvolvimento de parte desse trabalho.Ao professor João Bosco pela oportunidade, acreditar no meu trabalho e paciência.Ao professor Arnulfo que me ajudou a conseguir essa oportunidade e acreditou no meu trabalho. Aos colegas do LACOSEP pelo companheirismo e apoio.A todos os profissionais do Departamento de Engenharia Elétrica e de Computação pelo profissionalismo e dedicação. À Escola de Engenharia de São Carlos por todo suporte. À CNPq pelo apoio financeiro. RESUMO CARVALHO, E. O. P. Restabelecimento de Energia em Sistemas de Distribuição Considerando a Existência de Geração Distribuída . 2020. 124p.
The Network Reconfiguration (RR) process causes a change in the topology of the Distribution System (SD) through a plan to restore energy in real time, which in turn can cause an increase in the load current and change the short-circuit levels on some adjacent feeders. In view of this, some protection devices may operate in an undesirable manner. However, consideration of protection for the RR problem has been avoided in the literature, since it makes the problem even more complex. This work proposes to incorporate the phase and neutral overcurrent protection restrictions in the basic methodology of an AEMT (Multi-Objective Evolutionary Algorithm in Tables) for the problem of restoration in a radial SD. In this work, three-phase, two-phase faults with and without earth involvement and single-phase faults will be considered, in addition to the parameterization of the overcurrent relays for each SD feeder under analysis. The tests were carried out in an SD commonly used and found in the related technical-scientific literature. The results were promising for the proposed approach, it was observed that when including the protection restrictions the results were changed, showing the importance of considering this restrictions. Resumo: O processo de Reconfiguração de Redes (RR) provoca uma mudança na topologia do Sistema de Distribuição (SD) por meio de um plano de restabelecimento de energia em tempo real, que por sua vez pode ocasionar um aumento da corrente de carga e a alteração dos níveis de curto-circuito em alguns alimentadores adjacentes. Diante disso, alguns dispositivos de proteção podem operar de forma indesejável. No entanto, a consideração da proteção para o problema de RR tem sido evitada na literatura, uma vez que torna ainda mais complexo o problema. Este trabalho propõe incorporar as restrições de proteção de sobrecorrente de fase e neutro na metodologia base de um Algoritmo Evolutivo Multiobjetivo em Tabelas (AEMT) para o problema de restabelecimento em um SD radial. Neste trabalho serão consideradas faltas trifásicas, bifásicas com e sem o envolvimento da terra e monofásicas, além da parametrização dos relés de sobrecorrente para cada alimentador do SD em análise. Os testes foram realizados em um SD comumente empregado e encontrado na literatura técnico-científica correlata. Os resultados foram promissores para a abordagem proposta, observou-se que ao incluir as restrições de proteção a sequência de chaveamento foi alterada em alguns casos, mostrando a importância de considerá-las.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.