Background and purposePain after total knee arthroplasty (TKA) is usually severe, and epidural analgesia or femoral nerve block has been considered to be an effective pain treatment. Recently, local infiltration analgesia (LIA) has become increasingly popular but the outcome of this method regarding the analgesic effect has not been fully evaluated. We compared local infiltration analgesia and femoral block with regard to analgesia and morphine demand during the first 24 h after TKA.Methods40 patients undergoing TKA under spinal anesthesia were randomized to receive femoral nerve block (group F) or peri- and intraarticular infiltration analgesia (group LIA) with a mixture containing ropivacaine, ketorolac, and epinephrine. All patients had access to intravenous patient-controlled analgesia (PCA) with morphine postoperatively. Pain intensity at rest and upon movement was assessed on a numeric rating scale (0–10) on an hourly basis over 24 h if the patients were awake.ResultsThe average pain at rest was marginally lower with LIA (1.6) than with femoral block (2.2). Total morphine consumption per kg was similar between the 2 groups. Ancillary analysis revealed that 1 of 20 patients in the LIA group reported a pain intensity of > 7 upon movement, as compared to 7 out of 19 in the femoral block group (p = 0.04).InterpretationBoth LIA and femoral block provide good analgesia after TKA. LIA may be considered to be superior to femoral block since it is cheaper and easier to perform.
While the sympathetic nervous system seems to be involved in some pain states, the mechanisms linking the sensory and sympathetic nervous system are unclear. In this study the possible involvement of peripheral alpha-adrenoreceptors in the development of capsaicin induced ongoing pain and mechanical hypersensitivity was examined in humans. Intradermal capsaicin injections in the volar aspect of the arm gave rise to ongoing burning pain and dysesthesia as well as mechanical hypersensitivity. Ongoing pain and pain evoked by von Frey filament stimulation was rated on a numerical rating scale after intradermal capsaicin injection. The area of skin in which von Frey filament stimulation evoked pain was measured. A subcutaneous injection of phentolamine (alpha-adrenoreceptor antagonist) on one side and saline on the other side prior to the capsaicin injection was done to evaluate the role of the peripheral alpha-adrenoreceptors in development of capsaicin induced sensory symptoms and signs. Significantly less ongoing and evoked pain developed on the phentolamine injected side compared to the saline side, the latter in the area adjacent to the capsaicin injection (primary zone) and well outside the area of flare (secondary zone). The area in which pain could be evoked on the phentolamine injected side was restricted to the area of flare and was significantly smaller than on the saline injected side. Mechanical stimulation gave rise to aftersensation and radiation of pain on the saline injected side in all subjects but only in one case on the phentolamine injected side. Peripheral alpha-adrenoreceptors thus seem to be involved in functional changes of primary afferents which contribute to ongoing pain and mechanical stimulus evoked pain.
The objective of this study was to further explore the safety of Hemospan (Sangart Inc., San Diego, CA, USA), an oxygen-carrying plasma expander. The aim of this study was to determine if Hemospan is well tolerated in orthopaedic surgery patients with spinal anaesthesia in doses up to 1 L. Hemospan was previously found to be well tolerated in normal volunteers and orthopaedic surgery patients with spinal anaesthesia in doses up to 500 mL. Five cohorts of six orthopaedic surgery patients, American Society of Anesthesiologists (ASA) I and II, were studied. In each cohort, four patients received Hemospan in doses ranging from 200 to 1000 mL, and two received Ringer's lactate immediately prior to induction of spinal anaesthesia. There were no serious adverse events (SAEs). Iohexol clearance measured before and 24 h after dosing was unaffected. There were 14 adverse events (AEs) in the 10 control patients (1.4 per patient) and 30 in the 20 patients receiving Hemospan (1.5 per patient). One patient in the group receiving 200 mL Hemospan had elevated mean arterial pressure after dosing, but there were no elevations in any of the other patients. The peak plasma Hemospan concentration in the 1000 mL group was 1.3 g dL(-1), with a dose-dependent clearance (T(1/2)) ranging from 14.1 to 23.0 h. Plasma methaemoglobin levels were independent of dose, reaching a maximum at 40 h after dosing and never exceeded 0.125 g dL(-1). Troponin T was transiently elevated in two patients receiving Hemospan without symptoms or electrocardiographic abnormalities or elevation of myocardial creatinine kinase isoenzyme. Hemospan was well tolerated in this group of patients at doses up to 1000 mL.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.