Surgical implantation of the new FlowSecure artificial urinary sphincter is an easy procedure in males with stress urinary incontinence. Knigth et al. reported 30 to 40 minutes operating time, 4 days mean hospital stay and unnecessary pressurisation procedure in 3 out of their 9 patients. It seems that their results are reproducible.
Difundir el concepto de un nuevo esfínter urinario artificial con oclusión condicional para el tratamiento de la incontinencia urinaria de esfuerzo. El prototipo fue concebido y diseñado por los profesores Craggs M. y Mundy A.R. en el Instituto de Urología y Nefrología de Londres. Materiales y Métodos: El esfínter FlowSecure es un prototipo de una sola pieza de silicona llena de suero salino que consta de: 1) Un reservorio regulador de presión, 2) un reservorio de asistencia al estrés, 3) una bomba de control con un puerto autosellable y 4) un manguito. El reservorio regulador determina la presión de la prótesis y se puede ajustar desde 0 a 80 cm H 2 O mediante la inyección o extracción de líquido a través del puerto autosellable (oclusión basal). El reservorio de asistencia al estrés transmite de forma reversible los aumentos de la presión intra-abdominal durante los periodos de esfuerzo (oclusión condicional). Resultados: La técnica quirúrgica de implantación es simple, reduciendo la posibilidad de infección y errores de ensamblaje. La asociación en serie de un reservorio regulador de presión con un reservorio de asistencia al estrés permite establecer presiones de oclusión basal bajas y el aumento condicional de la misma durante los periodos de estrés, reduciendo el riesgo de atrofia y erosión. Tras la implantación, la presión es ajustable dependiendo de las necesidades clínicas del paciente. Discusión: El esfínter FlowSecure está diseñado para corregir la incontinencia ajustando la presión de oclusión según las necesidades individuales de cada paciente, así como para reducir las complicaciones asociadas al exceso de presión de oclusión y los fallos mecánicos. Palabras clave: Esfínter urinario artificial. Oclusión condicional. ABSTRACT "FLOWSECURE TM " ARTIFICIAL URINARY SPHINCTER: A NEW ADJUSTABLE ARTIFICIAL URINARY SPHINCTER CONCEPT WITH CONDITIONAL OCCLUSION FOR STRESS URINARY INCONTINENCE Introduction: To spread de concept of a new artificial urinary sphincter with conditional occlusion for stress incontinence. The new prototype was conceived and designed in The Institute of Urology and Nephrology of London by Professor Craggs M. and Professor Mundy A.R. Methods: The FlowSecure sphincter consists of an adjustable pressure-regulating balloon, a stress relief reservoir, a control pump and valve assembly unit with self-sealing port and a urethral cuff. The pressure regulating balloon determinates de operating pressure of the device; the pressure is adjustable in the range 0-80 cm H 2 O and can be altered by injection or removal of normal saline through the self sealing port. The stress relief balloon transmits transient intrabdominal pressure to the cuff during periods of stress. An adjustable circular urethral cuff minimises creasing and possible stress fractures. Results: The device is implanted as a one-piece assembly which is pre-filled with sterile saline. The surgical technique is simple and associated with little handling, reducing risk of infection and potential assembly errors. The adjustable pressur...
The new FlowSecure urinary artificial sphincter with conditional occlusion is designed to provide good continence rates adjusting regulating pressures when needed and conceived to reduce the risk of potential complications associated with excessive occluding pressures and mechanical failures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.