The non-invasive quantification of regional myocardial function is an important goal in clinical cardiology. Myocardial thickening/thinning indices is one method of attempting to define regional myocardial function. A new ultrasonic method of quantifying regional deformation has been introduced based on the principles of 'strain' and 'strain rate' imaging. These new imaging modes introduce concepts derived from mechanical engineering which most echocardiographers are not familiar with. In order to maximally exploit these new techniques, an understanding of what they measure is indispensable. This paper will define each of these modalities in terms of physical principles and will give an introduction to the principles of data acquisition and processing required to implement ultrasonic strain and strain rate imaging. In addition, the current status of development of the technique and its limitations will be discussed, together with examples of potential clinical applications.
For porcine myocardium, ultrasonic regional deformation parameters, systolic strain (epsilon(sys)) and peak systolic strain rate (SR(sys)), were compared with stroke volume (SV) and contractility [contractility index (CI)] measured as the ratio of end-systolic strain to end-systolic wall stress. Heart rate (HR) and contractility were varied by atrial pacing (AP = 120-180 beats/min, n = 7), incremental dobutamine infusion (DI = 2.5-20 microg. kg(-1). min(-1), n = 7), or continuous esmolol infusion (0.5 mg. kg(-1). min(-1)) + subsequent pacing (120-180 beats/min) (EI group, n = 6). Baseline SR(sys) and epsilon(sys) averaged 5.0 +/- 0.4 s(-1) and 60 +/- 4%. SR(sys) and CI increased linearly with DI (20 microg. kg(-1). min(-1); SR(sys) = 9.9 +/- 0.7 s(-1), P < 0.0001) and decreased with EI (SR(sys) = 3.4 +/- 0.1 s(-1), P < 0.01). During pacing, SR(sys) and CI remained unchanged in the AP and EI groups. During DI, epsilon(sys) and SV initially increased (5 microg. kg(-1). min(-1); epsilon(sys) = 77 +/- 6%, P < 0.01) and then progressively returned to baseline. During EI, SV and epsilon(sys) decreased (epsilon(sys) = 38 +/- 2%, P < 0.001). Pacing also decreased SV and epsilon(sys) in the AP (180 beats/min; epsilon(sys) = 36 +/- 2%, P < 0.001) and EI groups (180 beats/min; epsilon(sys) = 25 +/- 3%, P < 0.001). Thus, for normal myocardium, SR(sys) reflects regional contractile function (being relatively independent of HR), whereas epsilon(sys) reflects changes in SV.
The FRANCE TAVI registry provided reassuring data regarding trends in TAVR performance in an all-comers population on a national scale. Nonetheless, given that TAVR indications are likely to expand to patients at lower surgical risk, concerns remain regarding potentially life-threatening complications and pacemaker implantation. (Registry of Aortic Valve Bioprostheses Established by Catheter [FRANCE TAVI]; NCT01777828).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.