Background. Patients on kidney replacement therapy comprise a vulnerable population and may be at increased risk of death from coronavirus disease 2019 (COVID-19). Currently, only limited data are available on outcomes in this patient population. Methods. We set up the ERACODA (European Renal Association COVID-19 Database) database, which is specifically designed to prospectively collect detailed data on kidney transplant and dialysis patients with COVID-19. For this analysis, patients were included who presented between 1 February and 1 May 2020 and had complete information available on the primary outcome parameter, 28-day mortality. Results. Of the 1073 patients enrolled, 305 (28%) were kidney transplant and 768 (72%) dialysis patients with a mean age of 60 ± 13 and 67 ± 14 years, respectively. The 28-day probability of death was 21.3% [95% confidence interval (95% CI) 14.3–30.2%] in kidney transplant and 25.0% (95% CI 20.2–30.0%) in dialysis patients. Mortality was primarily associated with advanced age in kidney transplant patients, and with age and frailty in dialysis patients. After adjusting for sex, age and frailty, in-hospital mortality did not significantly differ between transplant and dialysis patients [hazard ratio (HR) 0.81, 95% CI 0.59–1.10, P = 0.18]. In the subset of dialysis patients who were a candidate for transplantation (n = 148), 8 patients died within 28 days, as compared with 7 deaths in 23 patients who underwent a kidney transplantation <1 year before presentation (HR adjusted for sex, age and frailty 0.20, 95% CI 0.07–0.56, P < 0.01). Conclusions. The 28-day case-fatality rate is high in patients on kidney replacement therapy with COVID-19 and is primarily driven by the risk factors age and frailty. Furthermore, in the first year after kidney transplantation, patients may be at increased risk of COVID-19-related mortality as compared with dialysis patients on the waiting list for transplantation. This information is important in guiding clinical decision-making, and for informing the public and healthcare authorities on the COVID-19-related mortality risk in kidney transplant and dialysis patients.
Background COVID-19 has exposed hemodialysis patients and kidney transplant recipients to an unprecedented life-threatening infectious disease raising concerns about kidney replacement therapy (KRT) strategy during the pandemic. The present study investigated the association of type of KRT with COVID-19 severity adjusting for differences in individual characteristics. Methods Data on kidney transplant recipients and hemodialysis patients diagnosed with COVID-19 between February 1st and December 1st 2020 were retrieved from ERACODA. Cox regression models adjusted for age, sex, frailty and comorbidities were used to estimate hazard ratios (HR) for 28-day mortality risk in all patients and in the subsets who were tested because of symptoms Results In total, 1,670 patients (496 functional kidney transplant and 1,174 hemodialysis) were included. 16.9% of kidney transplant and 23.9% of hemodialysis patients died within 28 days of presentation. The unadjusted 28-day mortality risk was 33% lower in kidney transplant recipients compared with hemodialysis patients (HR: 0.67, 95%CI: 0.52-0.85). In a fully adjusted model, the risk was 78% higher in kidney transplant recipients (HR: 1.78, 95%CI: 1.22-2.61) compared with hemodialysis patients. This association was similar in patients tested because of symptoms (fully adjusted model HR: 2.00, 95%CI: 1.31-3.06). This risk was dramatically increased during the first post-transplant year. Results were similar for other endpoints (e.g. hospitalization, ICU admission, mortality beyond 28 days) and across subgroups. Conclusions Kidney transplant recipients had a greater risk of a more severe course of COVID-19 compared with hemodialysis patients; they therefore require specific infection mitigation strategies.
Background. Available evidence suggests a reduced mortality risk for patients treated with high-volume postdilution hemodiafiltration (HDF) when compared with hemodialysis (HD) patients. As the magnitude of the convection volume depends on treatment-related factors rather than patient-related characteristics, we prospectively investigated whether a high convection volume (defined as ≥22 L/session) is feasible in the majority of patients (>75%). Methods. A multicenter study was performed in adult prevalent dialysis patients. Nonparticipating eligible patients formed the control group. Using a stepwise protocol, treatment time (up to 4 hours), blood flow rate (up to 400 mL/min) and filtration fraction (up to 33%) were optimized as much as possible. The convection volume was determined at the end of this optimization phase and at 4 and 8 weeks thereafter. Results. Baseline characteristics were comparable in participants (n = 86) and controls (n = 58). At the end of the optimization and 8 weeks thereafter, 71/86 (83%) and 66/83 (80%) of the patients achieved high-volume HDF (mean 25.5 ± 3.6 and 26.0 ± 3.4 L/session, respectively). While treatment time remained unaltered, mean blood flow rate increased by 27% and filtration fraction increased by 23%. Patients with <22 L/session had a higher percentage of central venous catheters (CVCs), a shorter treatment time and lower blood flow rate when compared with patients with ≥22 L/session. Conclusions. High-volume HDF is feasible in a clear majority of dialysis patients. Since none of the patients agreed to increase treatment time, these findings indicate that high-volume HDF is feasible just by increasing blood flow rate and filtration fraction.
In patients undergoing solid organ transplantation, the presence of an interleukin-1 (IL-1) driven disease may require the addition of IL-1 inhibiting drugs to the standard immunosuppressive regimen to protect against inflammation and negative graft outcome. Three patients undergoing renal transplantation were treated perioperatively with the interleukin-1 receptor antagonist anakinra. Kidney function increased rapidly in all three and the only complications seen were minor infections. In vitro studies report associations between serum and urinary levels of IL-1β and IL-1 receptor antagonist and negative graft outcome, and studies in animals and two small human trials illustrate a possible protective effect of anti-IL-1 therapy after solid organ transplantation. Peri-and postoperative use of anakinra is safe and effective in patients undergoing renal transplantation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.