Previously the National Health and Examination Survey measured physical activity with an accelerometer worn on the hip for seven days, but recently changed the location of the monitor to the wrist. PURPOSE This study compared estimates of physical activity intensity and type with an accelerometer on the hip versus the wrist. METHODS Healthy adults (n=37) wore triaxial accelerometers (Wockets) on the hip and dominant wrist along with a portable metabolic unit to measure energy expenditure during 20 activities. Motion summary counts were created, then receiver operating characteristic (ROC) curves were used to determine sedentary and activity intensity thresholds. Ambulatory activities were separated from other activities using the coefficient of variation (CV) of the counts. Mixed model predictions were used to estimate activity intensity. RESULTS The ROC for determining sedentary behavior had greater sensitivity and specificity (71% and 96%) at the hip than the wrist (53% and 76%), as did the ROC for moderate to vigorous physical activity on the hip (70% and 83%) versus the wrist (30% and 69%). The ROC for the CV associated with ambulation had a larger AUC at the hip compared to the wrist (0.83 and 0.74). The prediction model for activity energy expenditure (AEE) resulted in an average difference of 0.55 (+/− 0.55) METs on the hip and 0.82 (+/− 0.93) METs on the wrist. CONCLUSIONS Methods frequently used for estimating AEE and identifying activity intensity thresholds from an accelerometer on the hip generally do better than similar data from an accelerometer on the wrist. Accurately identifying sedentary behavior from a lack of wrist motion presents significant challenges.
Accurate, real-time measurement of energy expended during everyday activities would enable development of novel health monitoring and wellness technologies. A technique using three miniature wearable accelerometers is presented that improves upon state-of-the-art energy expenditure (EE) estimation. On a dataset acquired from 24 subjects performing gym and household activities, we demonstrate how knowledge of activity type, which can be automatically inferred from the accelerometer data, can improve EE estimates by more than 15% when compared to the best estimates from other methods.
Background: Physical behavior researchers using motion sensors often use acceleration summaries to visualize, clean, and interpret data. Such output is dependent on device specifications (e.g., dynamic range, sampling rate) and/or are proprietary, which invalidate cross-study comparison of findings when using different devices. This limits flexibility in selecting devices to measure physical activity, sedentary behavior, and sleep. Purpose: Develop an open-source, universal acceleration summary metric that accounts for discrepancies in raw data among research and consumer devices. Methods: We used signal processing techniques to generate a Monitor-Independent Movement Summary unit (MIMS-unit) optimized to capture normal human motion. Methodological steps included raw signal harmonization to eliminate inter-device variability (e.g., dynamic g-range, sampling rate), bandpass filtering (0.2–5.0 Hz) to eliminate non-human movement, and signal aggregation to reduce data to simplify visualization and summarization. We examined the consistency of MIMS-units using orbital shaker testing on eight accelerometers with varying dynamic range (±2 to ±8 g) and sampling rates (20–100 Hz), and human data (N = 60) from an ActiGraph GT9X. Results: During shaker testing, MIMS-units yielded lower between-device coefficient of variations than proprietary ActiGraph and ENMO acceleration summaries. Unlike the widely used ActiGraph activity counts, MIMS-units were sensitive in detecting subtle wrist movements during sedentary behaviors. Conclusions: Open-source MIMS-units may provide a means to summarize high-resolution raw data in a device-independent manner, thereby increasing standardization of data cleaning and analytical procedures to estimate selected attributes of physical behavior across studies.
To overcome problems with traditional methods for measuring stereotypical motor movements in persons with Autism Spectrum Disorders (ASD), we evaluated the use of wireless three-axis accelerometers and pattern recognition algorithms to automatically detect body rocking and hand flapping in children with ASD. Findings revealed that, on average, pattern recognition algorithms correctly identified approximately 90% of stereotypical motor movements repeatedly observed in both laboratory and classroom settings. Precise and efficient recording of stereotypical motor movements could enable researchers and clinicians to systematically study what functional relations exist between these behaviors and specific antecedents and consequences. These measures could also facilitate efficacy studies of behavioral and pharmacologic interventions intended to replace or decrease the incidence or severity of stereotypical motor movements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.