BackgroundAccurate prediction of mastectomy skin flap viability is vital as necrosis causes significant morbidity, potentially compromising results and delaying oncological management. Traditionally assessed by clinical judgement, a more objective evaluation can be provided using intraoperative imaging modalities. This systematic review aimed to compare all intraoperative techniques for assessment of mastectomy flap viability.MethodsA systematic literature review was performed using MEDLINE and Embase databases. Primary outcomes reported included specificity, sensitivity and predictive values of each test, and mean rates of mastectomy flap necrosis and reoperation. Secondary outcomes included cost analysis.ResultsSome 18 studies were included. Designs were prospective cohort study (8), retrospective case series (4), prospective case series (3), retrospective case–control study (1), prospective pilot trial (1) and cost analysis study (1). The studies compared indocyanine green angiography (ICGA) (16 studies) and fluorescein dye angiography (FA) (3 studies) with clinical judgement. Sensitivity and specificity were highest for ICGA (5 studies) ranging from 38 to 100 and 68 to 91 per cent respectively. Both methods overpredicted necrosis. Mean rates of flap necrosis and reoperation decreased with ICGA (7·9 and 5·5 per cent respectively) and FA (3 and 0 per cent) compared with clinical judgement (19·4 and 12·9 per cent). Two studies were designed to define numerical parameters corresponding to perfusion using intraoperative techniques. Two studies performed a cost analysis for ICGA; one claimed a cost benefit and the other advocated its use in high‐risk patients only.ConclusionICGA and FA are potentially useful tools for mastectomy flap assessment. However, the predictive accuracy is subject to the specific settings and model of equipment used. Current recommendations support their use in high‐risk patients.
Background. Three-dimensional (3D) photography provides a promising means of breast volumetry. Sources of error using a single-captured surface to calculate breast volume include inaccurate designation of breast boundaries and prediction of the invisible chest wall generated by computer software. An alternative approach is to measure differential volume using subtraction of 2 captured surfaces. Objectives. To explore 3D breast volumetry using the subtraction of superimposed images to calculate differential volume. To assess optimal patient positioning for accurate volumetric assessment. Methods. Known volumes of breast enhancers simulated volumetric changes to the breast (n = 12). 3D photographs were taken (3dMDtorso) with the subject positioned upright at 90° and posteriorly inclined at 30°. Patient position, breathing, distance and camera calibration were standardised. Volumetric analysis was performed using 3dMDvultus software. Results. A statistically significant difference was found between actual volume and measured volumes with subjects positioned at 90° ( P < .05). No statistical difference was found at 30° ( P = .078), but subsequent Bland–Altman analysis showed evidence of proportional bias ( P < .05). There was good correlation between measured and actual volumes in both positions (r = .77 and r = .85, respectively). Univariate analyses showed breast enhancer volumes of 195 mL and 295 mL to incur bias. The coefficient of variation was 5.76% for single observer analysis. Conclusion. Positioning the subject at a 30° posterior incline provides more accurate results from better exposure of the inferior breast. The subtraction tool is a novel method of measuring differential volume. Future studies should explore methodology for application into the clinical setting.
Highlights
Oro-facial fibrosis presents a significant disease burden in systemic sclerosis.
There is currently no treatment available for oro-facial fibrosis.
Autologous fat grafting is a novel therapeutic method for oro-facial fibrosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.