A new model of running shoes which features an extreme cushioning and an oversized midsole, known as the maximalist (MAX) was launched. This design claims to provide excellent shock absorption, particularly during downhill running. This study sought to assess the effects of MAX on the external impact loading, footstrike pattern, and stride length during level ground and downhill running on an instrumented treadmill. Twenty-seven distance runners completed four 5-minute running trials in the two footwear conditions (MAX and traditional running shoes (TRS)) on a level surface (0%) and downhill (10%-declination). Average and instantaneous loading rates (ILRs), footstrike pattern and stride length were measured during the last minute of each running trial. A 12% greater ILR was observed in downhill running with MAX (p = .045; Cohen's d = 0.44) as compared to TRS. No significant difference was found in the loading rates (p > .589) and stride length (p = .924) when running on a level surface. Majority of runners maintained the same footstrike pattern in both footwear conditions. Findings of this study suggested that MAX might not reduce the external impact loading in runners during level and downhill treadmill running. Instead, this type of footwear may conceivably increase the external impact loading during downhill treadmill running.
This study introduced a novel but simple method to continuously measure footstrike patterns in runners using inexpensive force sensors. Two force sensing resistors were firmly affixed at the heel and second toe of both insoles to collect the time signal of foot contact. A total of 109 healthy young adults (42 males and 67 females) were recruited in this study. They ran on an instrumented treadmill at 0°, +10°, and -10° inclinations and attempted rearfoot, midfoot, and forefoot landings using real time visual biofeedback. Intra-step strike index and onset time difference between two force sensors were measured and analyzed with univariate linear regression. We analyzed 25,655 footfalls and found that onset time difference between two sensors explained 80–84% of variation in the prediction model of strike index (R-squared = 0.799–0.836, p<0.001). However, the time windows to detect footstrike patterns on different surface inclinations were not consistent. These findings may allow laboratory-based gait retraining to be implemented in natural running environments to aid in both injury prevention and performance enhancement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.