Background and aims. All-on-four technique involves the use of tilted implants to allow for shorter cantilevers. This finite element analysis aimed at investigating the amount and distribution of stress in maxillary bone surrounding the implants with all-on-four vs. frequently used method with six implants technique using different numbers and inclination angles.Materials and methods. A 3D edentulous maxillary model was created and implants were virtually placed anterior to the maxillary sinus and splinted with a superstructure. In total, five models were designed. In the first to the fourth models, four implants were placed with distal implants inclined 0, 15, 30, and 45 degrees, respectively. In the fifth model, six vertical implants were placed. 100 N loading was placed in the left most distal region of the superstructure. Maximum von Mises stress values were evaluated in cancellous and cortical bone.Results. The maximum stress values recorded in cancellous and cortical bone were 7.15 MPa and 51.69 MPa, respectively (model I). The reduction in stress values in models II to V 6%, 18%, 54%, and 24% in cancellous bone and 12%, 36%,62%, and 62% in cortical bone, respectively.Conclusion. Increasing the inclination in posterior implants resulted in reduction of cantilever length and maximum stress decline in both cancellous and cortical bone. The effect of cantilever length seems to be a dominant factor which can diminish stress even with less number of implants.
Background and aims. Visfatin, mainly secreted by visceral adipose tissue, especially by macrophages, plays an important role in regulating the defense and immune functions, and functions as a growth factor, a cytokine, an enzyme and more importantly as a proinflammatory mediator. The aim of the present study was to evaluate the effect of non-surgical periodontal treatment on serum and salivary levels of visfatin in patients with generalized moderate-to-severe chronic periodontitis.Materials and methods. Eighteen patients with generalized moderate-to-severe chronic periodontitis were selected based on periodontal parameters of gingival index (GI), probing pocket depth (PPD), clinical attachment level (CAL) and radiographic parameters. Serum and salivary samples were collected at baseline and one month following non-surgical periodontal therapy (scaling and root planing ([SRP]). Visfatin levels were measured using an ELISA kit. Data were analyzed by SPSS 15, using paired t-test and Pearson's correlation coefficient.Results. Mean salivary and serum levels of visfatin significantly decreased after non-surgical periodontal treatment (P<0.05). Changes in salivary visfatin levels were more prominent.Conclusion. According to the findings of this study it seems that there is a direct relationship between periodontal tissue inflammation and disease activity with salivary and serum visfatin levels.
MGL tended to revert back to its original position following the use of SCTG, and this reversion is accompanied with an increase in the keratinized and attached gingival width.
Background. Since the misfit of crown has an important role in clinical performance of implant-supported prostheses, and due to the impact of the settling effect on misfit, the aim of this study was to investigate the impact of torque forces on the total lengths of narrow and short implant abutments in different internal implant‒abutment connections.
Methods. In four different implant‒abutment connections, 8 analog implants with a normal diameter (4 mm) and narrow abutment (4.5 mm) were selected from groups of internal hex, internal octagon, morse hex 6° and morse hex 11°. Each of them was mounted within plaster type IV, and 32 samples were obtained. Then, the amount of vertical displacement was measured by closing the impression copings and applying torques of 20 25 and 30 Ncm. This stage was repeated for the abutment. In the next stage, the resin pattern was built and measurements were performed after applying the torques mentioned. Finally, after making the frame, this stage was repeated, and the settling effect was statistically analyzed with ANOVA.
Results. In the stages of impression coping, resin pattern and final prosthesis, HEXAGONE had significantly the highest and OCTAGONE had the lowest rates of settling, and the settling of morse hex 11° and 6° was between them.
Conclusion. Octagon implant had significantly the lowest settling in various clinical and laboratory stages by applying different torques.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.